Installing the Unit

Use the following procedure to install the unit using the supplied
angle brackets. Refer to the OPTIONS AND ACCESSORIES
section near the back of this manual for other installation
options.
NOTE: Consult the manufacturer of the countertop material for
application information and surface temperature limits
before installing the unit.
NOTICE
Damage to any countertop material caused by heat
generated from Hatco equipment is not covered under
the Hatco warranty. Contact manufacturer of countertop
material for application information.
1. Position the unit on a flat surface with the halogen lights
facing down.
2. Install the angle brackets on each end of the unit.
NOTE: The angle brackets are shipped loose in the carton.
On each end of the unit:
a. Remove the two angle bracket screws.
b. Align the angle bracket with the mounting holes on the
unit. Secure the bracket with the two angle bracket
screws.
Angle Bracket
Angle Bracket Installation
NOTE: The angle brackets provide the required 1-1/2" (38 mm)
minimum clearance above the unit.
Form No. GRN4M-1017
3. Fasten the angle brackets to the underside of the shelf
using appropriate fasteners (not supplied by Hatco). Make
sure the unit is facing the desired direction with the wire
leads on the proper side before fastening the unit to the
shelf.
• A minimum gap of 1-1/2" (38 mm) is required between
4. Route the wire leads toward the installation location for the
control box.
Angle Bracket
Screw
7
the unit and the underside of a rolled or flanged edge of
the shelf to prevent heat damage to the electrical system
of the unit.
Flanged
Shelf
Angle
Bracket
Shelf Installation
INSTALLATION
1-1/2" (38 mm)
Minimum Gap