A
ß
Automatic mode:
Dry-Running Safety:
Leakage protection:
5. Storage
To put into storage:
b
a
Disposal:
(in accordance with
RL 2012/19/EU)
14
Adjusting the Cut-in and Cut-out Height:
The maximum cut-in height and minimum cut-out height
(see 8. Technical Data) can be adjusted by pushing the float
switch wire into the float switch lock.
v Press the cable of the float switch
the float switch lock
In order to ensure that the float switch is able to switch on and off,
9
the cable length between the float switch and the float switch lock
must be at least 10 cm.
4000/2 automatic (Art. No. 1742):
The pump automatically switches off as soon as no more water is
retrieved. Due to the non-return valve, the pressure is maintained
in the hose until water is drawn via the hose. When water is drawn
via the hose (the pressure in the hose falls below approx. 1.3 bar),
the pump switches on automatically.
When there is no liquid to pump, the pump automatically switches
off. The pump then switches in the cycle on 30 sec. – 5 sec.
off (4 x). In 1 hr., 5 hrs., 24 hrs., 24 hrs.... this cycle is repeated.
As soon as the pump stands in at least 4.5 cm water, the pump
is ready for operation again.
If there is leakage on the pressure side (e. g. a leaking pressure
hose or connecting device), the pump automatically switches on
and off in short intervals. When the pump switches on and off
more frequently than 7 x in 2 min. (with a leakage less than 90 l/h),
the pump switches completely off. When the leakage on the
pressure side is eliminated, the pump must be unplugged and
plugged in again in order to be operational again.
The storage location must not be accessible to children.
The pump must be protected against frost.
1. Unscrew the telescopic lance
and empty the pump (turn the
pump upside down).
2. Store the pump in a dry, frost-
proof location.
Transport position:
1. Unscrew telescopic pipe
attach to the side of pump.
Here, ensure that the nose
slid into the slot
2. Wind mains cable
cable holder
connector
In the transport position, the pump can be carried by the
telescopic pipe
push up the slide bar
The product must not be added to normal household waste.
It must be disposed of in line with local environmental regulations.
ß
.
A
3
3
and
is
a
.
b
6
around the
0
and the pump
4
.
3
. For easier winding of the mains cable
q
of the cable holder
9
into an opening in
3
6
,
0
.
4
6
q
0