Service Life Record

Oxy K 30 HW
— located at the side of wall holder.
Date of Manufacture
Serial No.
Enter delivery date with care!
To prevent damage to the oxygen self-rescuer, do not stamp figures
on.
Dräger recommend engraving or etching.
Date
Responsible
for entry
Date of
Dräger
manu-
facture
Serial no.
Dräger
Delivery
End user
date
Oxy K 30 HS/HS KD
The inspection intervals for the Oxy K 30 HS/HS KD depend on the
use and storage.
— Storage:
If the Oxy K 30 HS/HS KD is stored, no inspection intervals are
required. After ten years, the unit's lifetime is over, and the oxygen
self-rescuer must be disposed.
1)
— Use
:
If the Oxy K 30 HS/HS KD is used, the following inspection inter-
vals are relevant. (If the Oxy K 30 HS/HS KD is both stored and
used, all the inspection intervals should be followed.)
Characteristic
Completeness of oxygen
1)
self-rescuer
Lid closed
seal undamaged
Housing incl. indicator
2)
undamaged
Deep blue colour of
3)
indicator
4)
Weight check
End of lifetime
1) The oxygen self-rescuer has to be complete. No parts should be mis-
sing
such as a clamp, opening mechanism etc.
2) The housing must be airtight. No cracks, dents or other defects deeper
than 1.5 mm. The indicator window must not be damaged.
3) Indicator shows deep blue colour – if there is a significant loss of blue
colour (50 % of the particles have changed colour from dark blue to
pink or neutral) the oxygen self-rescuer has to be taken out of service.
4) The oxygen self-rescuer's first weight check must be performed on deli-
very.
If one of the above mentioned criteria is not in line, the
oxygen self-rescuer has to be taken out of service.
— Oxygen self-rescuers with damaged indicator window or seal can
be repaired with reference to the Dräger "service life plan".
— If the oxygen self-rescuer has experienced unusual conditions
(punch, pressure etc.), it has to be checked immediately.
1) Single shift operation max. 8 h a day, 5 working days a week; during
multi shift operation the intervals will reduced accordingly.
Delivery Date
Date to be
Notes
entered
Month and
year of
manufacture
Registration
no.
Month and
Usable period =
year of
delivery date +
delivery
10 years
dail
3 Y. 5 Y. 7 Y. 9 Y. 10 Y.
y
X
X
X
X
X
X
X
X
X

Order List

Oxy K 30 HW
Designation and description
Oxygen self-rescuer Oxy K 30 HW
Training unit Oxy K 30 HWT
Dräger Transport packaging
Seal, orange
Indicator window
Pictograph
Reflector stripes (top)
Reflector stripes (bottom)
Oxy K 30 HS/HS KD
Designation and description
Oxygen self-rescuer Oxy K 30 HS
Oxygen self-rescuer Oxy K 30 HS KD
Training unit Oxy K 30 HST
Dräger Transport packaging
Seal, orange
Indicator window
Order No.
63 04 600
63 04 601
63 04 511
63 04 504
67 33 647
63 04 598
63 04 503
63 01 996
Order No.
63 04 700
63 04 703
63 04 701
63 04 511
63 03 297
67 33 647