SATAjet H | 5
objects; the smallest amount of damage will badly influence
the spray pattern. Use SATA nozzle cleaning needles.
d) To ensure maximum sealing the edge of cup must always be
kept clean.
e) Apply SATA special grease (Art. No. 48173) to moving parts
if necessary.
Note!
Paint spray gun may be cleaned with solvent or cleaning
agents manually or in a conventional gun washing machine.
The procedures mentioned below will damage the paint
spray gun/system and may lead to expiry of the explosion
proofness certificate as well as total loss of any waranty:
• Immersing the paint spray gun in solvent or cleaning agents,
or for a period longer than required for the cleaning process
as such
• Failure to remove the paint spray gun from the gun washing
machine after finishing the cleaning process
• Cleaning the paint spray gun by means of ultrasound clean-
ing systems
Warning! Attention!
When using solvents and cleaning agents based on halogen-
ated hydrocarbons e.g. 1.1.1-trichlorethylene and methylene
chloride, chemical reactions can occur on the aluminium cup,
gun and on galvanized components (small quantities of water
added to 1.1.1-trichlorethyelene produce hydrochloric acid).
This can cause oxidation of the components; in extreme cases,
the reaction can be explosive.
Therefore only use solvents andcleaning agents for your paint
gun which do not contain the substances named above. You
must never use acid, alkaline solutions / Iye or stripping agents
for cleaning.
6. Troubleshooting
Malfunction
Cause
Paint spray gun
Foreign substances
leaks from fluid tip.
between fluid tip
and needle prevent
sealing.
Paint emerges from
Self tensioning
fluid needle - needle
needle sealing
sealing.
damaged or lost.
Paint spray flutters.
Too little material
in cup, fluid noz-
zle not tight self-
adjusting, needle
sealing damaged,
nozzle set dirty or
damaged.
Material bubbles or
Atomization air
„boils" in paint cup.
flows through the
paint channel to
the cup. The paint
nozzle is not suf-
ficiently tightened.
Air nozzle is not
completely screwed
on, the air net
clogged.
7. Warranty
During the period of twelve (12) months from the date of original
purchase Würth will repair or, replace the product without charge
for parts or labour subject to the following conditions.
The warranty covers the value for production parts or defects in
material during the warranty period. The warranty does not include
damages caused by improper handling, normal wear and tear,
mechanical damages, faulty assembly, improper maintenance,
unusual spray materials, substitute materials, chemicals such as
alkaline solutions and acids, electro-chemical or electric influences,
as far as this damage is not the result of any error committed by us.
Abrasive spray material such as red lead and liquid grinding material
etc. reduce the lifetime of valves, packings, guns and nozzles. Wear
and tear damage caused by this are not covered in this warranty.
Units should be inspected upon delivery by the consumer.
Obvious damage must be reported within 14 days of receipt of
the unit to the supplier to avoid loss of the right to claim notice
of defects.
Additional claims such as compensation are excluded. This
refers as well to damages caused during meetings , training ses-
sions, or demonstrations. Should the consumer require immedi-
ate repair or replacement before a determination of whether
the affected unit is covered by the warranty, the repair or the
replacement will be made and charged at the current prices. If it
is determind that the item is covered by the warranty, a credit will
be issued for the repair or replacement. Replaced parts become
the property of Würth or their distributor.
Notice of defects or other claims do not entitle the consumer to
delay or refuse payment.
Returned merchandise to SATA must be sent prepaid. All service
charges, freight and handling charges are to be paid by the con-
sumer. The charges made will be in line with currently existing
pricing. Suretyships may not prolong the warranty period. This
warranty terminates upon unauthourised inference.
Corrective Action
Remove and clean
fluid needle and
fluid nozzle or use
new nozzle set.
Replace needle
sealing.
Refill material,
tighten parts, if
necessary clean or
replace parts.
Tighten parts
accordingly, clean
or replace.
EN