BFT ARES ULTRA BT A 1000 Instructions D'utilisation Et D'installation page 20

Actionneur pour portails coulissants à crémaillère
Masquer les pouces Voir aussi pour ARES ULTRA BT A 1000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Logic
Definition
Configuration of
EXPI2 input
on input-output
EXPI2
expansion board.
1-3
Configuration of
EXPO2 output
on input-output
EXPO1
expansion board
4-5
Configuration of
EXPO2 output
on input-output
EXPO2
expansion board
6-7
Traffic light pre-
TRAFFIC LIGHT
flashing
PREFLASHING.
TRAFFIC LIGHT
Steadily lit red
RED LA P ALWAYS
light
ON
*
Only active on FW ≥ 2.10
TABLE "C" – RADIO MENU (RADIO)
Logic
Description
Add Start Key
Add start
associates the desired key with the Start command
Add 2ch Key
Associates the desired key with the 2nd radio channel command. If no output is configured as 2nd Radio Channel Output, the 2nd radio chan-
add 2ch
nel controls the pedestrian opening.
Erase List
WARNING! Erases all memorized transmitters from the receiver's memory.
erase 64
Read receiver code
Displays receiver code required for cloning transmitters.
ON = Enables remote programming of cards via a previously memorized W LINK transmitter.
It remains enabled for 3 minutes from the time the W LINK transmitter is last pressed.
OFF= W LINK programming disabled.
32 -
ARES ULTRA BT A 1000 - ARES ULTRA BT A 1500
INSTALLATION MANUAL
Cross out
De-
setting
fault
used
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
0
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing the
*
11
movement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening the
*
12
movement stops.
0
Output configured as 2
1
Output configured as SCA (gate open light).
11
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
4
Output configured as Stair Light.
5
Output configured as Alarm.
6
Output configured as Flashing light.
7
Output configured as Latch.
11
8
Output configured as Magnetic lock.
9
Output configured as Maintenance.
10
Output configured as Flashing Light and Maintenance.
11
Output configured as Traffic Light control with TLB board.
0
Pre-flashing switched off.
0
Red lights flash, for 3 seconds, at start of operation.
1
0
Red lights off when gate closed.
0
Red lights on when gate closed.
1
Optional extras
Radio Channel.
nd