TABLE "B" - LOGIC MENU - (logic)
Logic
Definition
Automatic Clo-
TCA
sing Time
Fast closing
FAST CLS.
Step-by-step
STEP-BY-STEP
movement
OVE NT
Pre-alarm
PRE-ALAR
Deadman
HOLD-TO-RUN
Block pulses
IBL OPEN
during opening
Block pulses
*IBL TCA
during TCA
Block pulses
IBL CLOSE
during closing
Ice feature
ICE
Open in other
OPEN IN OTHER
direction
DIRECT.
INSTALLATION MANUAL
Cross out
De-
setting
fault
used
0
Logic not enabled
0
1
Switches automatic closing on
0
Logic not enabled
0
1
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
Inputs configured as Start E, Start I, Ped
0
operate with 4-step logic.
Inputs configured as Start E, Start I, Ped op-
1
erate with 3-step logic. Pulse during closing
0
reverses movement.
Inputs configured as Start E, Start I, Ped op-
2
erate with 2-step logic. Movement reverses
with each pulse.
0
The flashing light comes on at the same time as the motor(s) start.
0
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
0
Pulse operation.
Deadman mode.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
1
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
WARNING: safety devices are not enabled.
0
Emergency Deadman mode.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, Deadman mode is
enabled which will stay active for 1 minute after the OPEN UP - CLOSE UP keys are released.
2
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
0
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during TCA pause.
0
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during TCA pause.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during closing.
0
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during closing.
0
The Amperostop safety trip threshold stays at the same set value.
The controller automatically adjusts the obstacle alarm trip threshold at each start up.
Check that the force of impact measured at the points provided for by standard EN 12445 is lower than the
0
1
value laid down by standard EN 12453. If in doubt, use auxiliary safety devices.
This feature is useful when dealing with installations running at low temperatures.
WARNING: once this feature has been activated, you will need to perform an autoset opening and closing cycle.
0
Standard operating mode (See Fig.Q Ref. 1).
0
1
Opens in other direction to standard operating mode (See Fig. Q Ref.2)
Optional extras
step-by-step mov.
2 STEP
CLOSED
OPENS
DURING
CLOSING
OPEN
CLOSES
DURING
OPENING
AFTER STOP
OPENS
Usually pulse operation.
ARES ULTRA BT A 1000 - ARES ULTRA BT A 1500 -
3 STEP
4 STEP
OPENS
OPENS
STOPS
CLOSES
CLOSES
STOP + TCA STOP + TCA
OPENS
OPENS
29