Logic
Definition
Configuration
of safety input
SAFE 1
SAFE 1.
72
Configuration
of safety input
SAFE 2
SAFE 2.
74
Configuration of
command input
IC 1
IC 1.
61
Configuration of
command input
IC 2
IC 2.
62
Configuration of
AUX 0 output.
AUX 0
20-21
Configuration of
AUX 3 output.
AUX 3
26-37
Fixed code
FIXED CODE
30 -
ARES ULTRA BT A 1000 - ARES ULTRA BT A 1500
INSTALLATION MANUAL
Cross out
De-
setting
fault
used
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
0
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
Input configured as Bar 8k2.
Input configured as Bar OP, safety edge with inversion active only while opening. If while closing, the mo-
*
9
vement stops.
Input configured as Bar OP TEST, safety edge tested with inversion active only while opening. If while closing,
*
10
6
the movement stops.
Input configured as Bar OP 8k2, safety edge with inversion active only while opening. If while closing, the
*
11
movement stops.
Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the mo-
*
12
vement stops.
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while opening,
*
13
the movement stops.
Input configured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening, the
*
14
movement stops.
0
Input configured as Start E.
1
Input configured as Start I.
0
2
Input configured as Open.
3
Input configured as Close.
4
Input configured as Ped.
4
5
Input configured as Timer.
6
Input configured as Timer Pedestrian.
0
Output configured as 2nd Radio Channel.
1
Output configured as SCA (gate open light).
6
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
4
Output configured as Stair Light
5
Output configured as Alarm
6
Output configured as Flashing light
7
Output configured as Latch
0
8
Output configured as Magnetic lock
9
Output configured as Maintenance
10
Output configured as Flashing Light and Maintenance.
Receiver is configured for operation in rolling-code mode.
0
Fixed-Code Clones are not accepted.
0
Receiver is configured for operation in fixed-code mode.
1
Fixed-Code Clones are accepted.
Optional extras