General

Hatco Round Heated Shelves are designed for ease of operation.
Perform the following procedure to operate the unit.
WARNING
Read all safety messages in the IMPORTANT SAFETy
INFORMATION section before operating this equipment.
1. Plug the unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. See the
SPECIFICaTIONS section for details.
2. move the Power On/Off switch to the On position.
3. allow the unit 15–20 minutes to reach operating temperature.
CAUTION
Make sure food product has been heated to the proper
food-safe temperature before placing in unit. Failure to heat
food product properly may result in serious health risks.
This unit is for holding pre-heated food product only.
BURN HAzARD: Some exterior surfaces on unit will get hot.
Use caution when touching these areas.
Thermostat
Access
Plug
Power
On/Off
Switch
Control Panel (Bottom View)
Form No. GRSRm-1112
Indicator
Light

Thermostat Adjustment

The thermostat adjustment screw is located on the side of the
unit behind the thermostat access plug. Units are supplied from
the factory with the temperature control thermostat set on high.
If adjustment is needed, use the following procedure.
1. move the Power On/Off switch to the Off position, unplug
the power cord, and allow unit to cool.
2. Remove the thermostat access plug.
3. Turn the adjustment screw using a small screwdriver.
• Turn the screw counterclockwise to decrease the
temperature or clockwise to increase the temperature.
NOTE: Do not turn the screw more than 1/8 turn at a time.
4. Plug in the power cord and move the Power On/Off switch to
the On position. allow at least five minutes for temperature
to stabilize.