Riello START 28 KI Manuel D'installation Et D'utilisation page 8

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

START KI - KIS
ADJUSTMENT OF HEATING WATER TEMPERATURE
To adjust the heating water temperature, turn the mode selector to
within the adjustment range (turn clockwise to increase the value and
anticlockwise to reduce the value).
HEATING WATER
TEMPERATURE
SUMMER: the standard domestic hot water-only mode is activated
by turning the selector to the summer symbol
automatically in response to a request for domestic hot water. The
digital display indicates the temperature of the domestic hot water.
SUMMER
MODE
PRE-HEATING (faster hot water)
Turning the domestic hot water adjustment knob to the symbol
activates the pre-heating function. Bring the domestic hot water
temperature adjustment knob back to the required position. This
function keeps the water in the domestic hot water exchanger to reduce
standby times when a request is made. When the pre-heating function
is enabled, the display shows the symbol
the outlet temperature of the heating water or the domestic hot water
based upon the request in progress. During burner ignition, following
a pre-heating request, the monitor shows the flashing
deactivate the pre-heating function, rotate the domestic hot water
temperature adjustment knob back to the symbol
switches off. Return the domestic hot water temperature adjustment
knob to the desired position. The function is not active when the boiler
is OFF: function selector on
PRE HEATING
MODE
DHW temperature adjustment
To adjust the domestic hot water temperature (for baths, showers,
kitchen etc.), turn the dial with the
the value, or anticlockwise to decrease the value (mi. value 37°C -
max. value 60 °C). The boiler is in standby until the burner switches
on following a heat request. The boiler continues to function until
the temperatures set on the boiler are reached, or the heat request
terminates; it will then go back to standby. In the case of a temporary
stop the digital display shows the fault code.
DHW TEMPERATURE
ADJUSTMENT
8
DOMESTIC HOT WATER
TEMPERATURE
, the boiler lights
. The display indicates
symbol. To
. The symbol
OFF
symbol clockwise to increase
Heating Temperature Control function (C.T.R.)
Turn the heating water temperature selector into sector highlighted with
white markers to activate the H.T.C. self-adjusting system: based on the
temperature set on the ambient thermostat and the time employed to
reach it, the boiler varies automatically the heating water temperature
reducing the operating time, allowing great operation comfort and
energy saving.
C.T.R. FUNCTION
Unblock function
To restore operation, turn the function selector to
seconds and then set the function selector to the required position.
The boiler restarts automatically.
NOTE: if the unblock attempts do not restart the boiler, contact the
Technical Support Centre.
4.3
Checks during and after commissioning
After commissioning, ensure that the START boiler runs the start-up
and subsequent shutdown procedure correctly using the:
- function selector
- calibration of the heating water temperature selector and DHW
temperature selector
- required room temperature (adjusting the room thermostat or timer).
Check operation in DHW mode by opening a hot water tap with the
function selector set to Summer mode and to Winter mode.
Check that the boiler stops completely when turning the main system
switch to "OFF".
Operate the appliance continuously for a few minutes by turning the
main switch to "ON", setting the function selector to Summer and
keeping the DHW utility tap on. The processing binders and residue
evaporate and the following can be checked:
- supply gas pressure
- combustion.
Supply gas pressure check
- Turn the main system switch to "OFF".
- Unscrew the case screws (A).
START
28 KI-28 KIS
START
24 KIS
OFF, wait 5-6
A
A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Start 24 kisStart 28 kisStart 35 kis

Table des Matières