14 | Communication Série
Paramètre
LOC_AUDIO_THRESHOLD
MEASURE_UNIT
CORR_VALUE
MEAS_GAS
MEAS_GAS_VISCOSITY
MEAS_GAS_DENSITY
MEAS_GAS_SHOW
48 / 84
Read
Sequence
Answer
of Data
rP18\n
Locating Audio
Threshold (%):
[value]
rP19\n
Measuring Unit:
[text]
rP20\n
Correlation Value:
[value]
rP21\n
Displayed Gas:
[text]
rP22\n
Displayed Gas
Viscosity (µPas):
[value]
rP23\n
Leak Gas Density
(g/l): [value]
rP24\n
Displayed Gas
Name: [text]
Write
Sequence
of Data
wP18 [value]\n
wP19 [text]\n
wP20 [value]\n
wP21 [text]\n
wP22 [value]\n
wP23 [value]\n
wP24 [text]\n
Sensistor_Sentrac_Strix_mode_d'emploi_ninb65fr1-01-(2011)
INFICON
value/text
0 - 100
Dans le cas de cc/s, Pa
3
m
/s, cc/in, SCCM, g/
3
yr, oz/yr, mbarl/s, mm
3
s, mm
/min, la
conversion
automatique est
activée. 14 caractères
maximum.
Dans le cas de 95%N
2
- 5%H
, Air, He, N
, H
2
2
2
R123a, R22, R290,
R404a, R407c, R410,
R600a, R1234yf, la
conversion
automatique est
activée. 14 caractères
maximum.
Activé lorsque le gaz
de fuite n'est pas réglé
sur : 95%N
- 5%H
,
2
2
Air, He, N
, H
, R123a,
2
2
R22, R290, R404a,
R407c, R410, R600a,
R1234yf
Activé lorsque le gaz
de fuite n'est pas réglé
sur : 95%N
- 5%H
,
2
2
Air, He, N
, H
, R123a,
2
2
R22, R290, R404a,
R407c, R410, R600a,
R1234yf
0 = Actif
1 = Inactif
/
,