2. Press the INC. button to show the total resistance, the highest resistance and the lowest
resistance.
TOTAL: 28 mΩ
H: 12mΩ L: 5mΩ
If the battery is connected to the main socket only, the total resistance will be
displayed.
If a lithium battery is connected to the charger via the balance charging socket, the
resistance of each cell, the total resistance, the highest resistance and the lowest
resistance will be displayed.

19. WARNING AND ERROR MESSAGES

In case of an error the display will show the cause of error and emit an audible sound.
REVERSE POLARITY
CONNECTION BREAK
CONNECTION ERROR
CHECK MAIN PORT
BALANCE CONNECT
ERROR
DC IN TOO LOW
DC IN TOO HIGH
CELL ERROR
LOW VOLTAGE
CELL ERROR
HIGH VOLTAGE
CELL ERROR
VOLTAGE- INVALID
63
Incorrect polarity connected
The connection is interrupted
The battery connection is wrong
The balance connection is wrong
Input voltage is less than 11 V
Input voltage is higher than 18 V
Voltage of one cell in the battery pack is too low
Voltage of one cell in the battery pack is too high
Voltage of one cell in the battery pack is invalid