VOLTCRAFT 1209050 Notice D'emploi page 59

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Item
Safety Timer
ON
120Min
Capacity Cut-Off
ON
5000mAh
Temp Cut-Off
ON 50˚C 122˚F
Temperature Unit
Celsius
Rest Time
CHG>DCHG 10Min
NiMH Sensitivity
D. Peak
Default
NiMH Sensitivity
D. Peak
Default
59
Selection
OFF/ON (1 - 720 min)
OFF/ON (100 - 50000
mAh)
OFF/ON (20 ˚C/68 ˚F - 80
˚C/176 ˚F)
Celsius/Fahrenheit
1 - 60 min
Default: 4 mV/Cell
5-15 mV/Cell
Description
When a charge program is
started, the safety timer also
starts automatically. This can
prevent overcharging the battery
if it proves to be faulty, or if the
termination circuit cannot detect
the full battery. The value for the
safety timer should be generous
enough to allow a full charge of
the battery.
This sets the maximum charging
capacity to be supplied to the
battery during charging. In case
the delta peak voltage is not
detected or the safety timer does
not expire for any reason, this
feature will automatically stop the
process at the selected capacity
value.
The battery's internal chemical
reaction
will
cause
temperature of the battery to rise.
If the temperature limit is reached,
the process will be terminated.
Select a desired temperature unit
A rest time allows the battery to
cool down between charging/
discharging cycles.
This is for NiMH/NiCd battery
only. When the delta peak value
reaches the value you set, the
charger will show the battery is
fully charged.
the

Publicité

Table des Matières