Motor does not run
Undervoltage relay tripped by power fail-
ure:
 switch on again.
No mains voltage
 check cable, plug, outlet and mains
fuse.
Band saw blade wanders off the line
of cut or runs off the band saw
wheels
Band saw blade is not running properly
on the band saw wheels:
 Correct tracking (see "Care and
Maintenance").
Band saw blade breaks
Incorrect tension:

14. Technical specifications

Voltage
Nominal current
Fuse protection
Protection rating
Protection class
Performance
Power input P1
effective shaft output P2
Rated no-load speed
Cutting speed
Band saw blade length
Max. throat capacity
Max. capacity under guide
Max. band saw blade width
Max. band saw blade thickness
Dimensions
Machine in packing
 Length
 Width
 Height
Machine ready for work (saw table horizontal)
 Length
 Width
 Height
Saw table only
 Length
 Width
Weight
Machine ready for work (with accessories supplied)
Permissible ambient temperature for operation
Permissible temperature for transport and storage
Noise emission value (DIN EN 1870-1*) at idle
A-sound pressure level L
pA
A-sound power level
LWA
Uncertainty K
 correct band saw blade tension (see
"Care and Maintenance").
Load too high:
 reduce pressure against band saw
blade (reduced feed rate).
Incorrect band saw blade:
 replace band saw blade (see "Care
and Maintenance"):
Contour cuts = 
narrow band saw blade,
Straight cuts = 
wide band saw blade.
Band saw blade warped
Load too high:
 avoid lateral pressure on the band
saw blade.
V
A
A
kW
kW
-1
min
m/min
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
kg
° C
° C
dB (A)
dB (A)
dB (A)
Saw vibrates
Insufficient mounting:
 Fasten saw properly to a suitable
floor (see "Initial Operation").
Saw table loose:
 Align and fasten saw table.
Motor mount loose:
 Check fastening screws, tighten if
necessary.
Dust extraction port blocked
No dust collector connected or suction
capacity insufficient:
 Connect a dust collector or increase
suction capacity (air speed 20 m/
sec at dust extraction port).
WNB
230 (1~ 50 Hz)
6,7
10 (time-lag or K-Auto-
mat)
IP 54
I
1.50 kW S6 40%
1.10 kW S6 40%
1400
408/965
3380
440
280
25
0,65
790
710
1970
834
639
1860
640
536
133
0 to +40
0 to +40
75,0
84,6
4,0
ENGLISH
DNB
400 (3~ 50 Hz)
3,9
10 (time-lag or K-Auto-
mat)
IP 54
I
1.90 kW S6 40%
1.50 kW S6 40%
1400
408/965
3380
440
280
25
0,65
790
710
1970
834
639
1860
640
536
133
0 to +40
0 to +40
75,0
84,6
4,0
25