Using medolight
EN
Medolight is used for light therapy with light emitted by electro-
luminescent diodes (LED) in red and infrared wavelengths range.
BG
CS
DE
control diodes
control diode
• exposure time (1–5)
battery level (Batt. diode)
FR
• programme number (1–5)
HR
HU
ON
TIME
MODE
START
IT
OFF
PL
ON/OFF
TIME
MODE
RO
turns the
sets
changes the
power
exposure
exposure
RU
on and off
duration
programme
SK
SR
socket to connect
UA
YS10MB power supply
adaptor-charger
AR

General safety information

During use all the safety precautions which apply to electrical
devices must be followed; specifically:
Please read the manual carefully before operating and follow the
instructions therein. It is recommended to complete training with
a seller.
Note: Use of control elements, settings or execution of other proce-
dures than those specified in this manual may result in uncontrolled
exposure to light.
Do not direct light towards your eyes. In case of face exposure close
your eyes.
Treatment area should be exposed from a distance of 5mm.
Handle the device with care: protect from mechanical damage, fall,
moisture and high temperature.
Do not submerge the device and the charger in water or other
liquids.
The device should not be exposed to direct sunlight.
Do not use the device or the charger if their casings have been
damaged.
Use only YS10MB charger provided with medolight package. The
use of other charger may damage the device. YS10MB charger
should be used only with medolight device. The use for other
START
purposes may damage the charger.
When using the device with the charger exercise particular caution
starts the
– keep away from children.
session
If necessary use an approved extension cord.
Do not open the casings and do not make repairs yourself. In case
of the improper work of the device, repair should be conducted
only by an authorized service provider.
WARNING:
The device is a source of heat.
The device contains a battery, which may be harmful for the
environment – dispose only into a used battery storage con-
tainer.
4
Packaging, the device and the charger casings and manual are
recyclable.

Turning the device on and off

Before starting up the device for the first time there should be
carried out 3 hours battery charging process - see page 7 - battery
status signaling.
The device is turned on and off with the ON/OFF button.
After turning on a testing programme is run – control diodes 1–5
and the Batt. diode consecutively lit up.
The device automatically sets the first exposure programme and
exposure duration to 5 minutes (control diode 1 is lit up).
At the same time the Batt. diode is lit up for 5 seconds, indicating
the battery level. (see chapter "Battery level indicator").
If within 1 minute since turning the device on no control button is
pressed, the device will switch into the stand-by mode – no control
diode is lit up, the device "remembers" the last setting. The device
can be switched back into the active mode by pressing one of the
three buttons: TIME, MODE or START.
Exposure duration selector
Use TIME button to select one of five exposure durations: 5, 10, 15,
20, 25 minutes.
After turning the device on with ON/OFF button, the 5 minute
exposure duration is selected automatically. Each depression of TIME
button increases the duration by 5 minutes, causing another control
diode to light up for 5 seconds.
After 5 seconds or after pressing the MODE button, the device auto-
matically reverts to the selected exposure programme.
Exposure duration selector
5
mins.
ON
TIME
MODE
START
OFF
10
mins.
ON
TIME
MODE
START
OFF
15
mins.
ON
TIME
MODE
START
OFF
20
mins.
ON
TIME
MODE
START
OFF
25
mins.
ON
TIME
MODE
START
OFF
5
EN
BG
CS
DE
FR
HR
HU
IT
PL
RO
RU
SK
SR
UA
AR

Publicité

Table des Matières
loading

Table des Matières