Malfunction
The machine will not start. The voltage supply has not been prop-
The grinding pattern is un-
even.
The machine shuts down
independently.
Cause
erly connected.
The connecting cable is defective.
A capacitor is defective
(ES 51S / STR 701L)
Faulty power supply.
A safety switch is defective.
Tools are loose.
Tools are damaged or worn.
The machine is overloaded.
The drive overload protection has trig-
gered.
The connecting cable's cross-section is
too small.
Rectification
Connect the connecting cable (exten-
sion cable) with a proper power socket.
Replace the connecting cable.
Replace both capacitors
Use a different power socket if neces-
sary.
Replace the safety switch.
Fasten tools.
Replace tools.
—
Reset:
a.
Wait 30 seconds.
b.
Restart the machine
(! Chapter 3.1).
—
If the drive overload protection
trips repeatedly, the machine
must be allowed to wind down
(mount other potential tools), oth-
erwise motor damage could re-
sult!
Check the connecting cable and re-
place if necessary.
25