The fan does not work while
the plug is in the socket and
the switch is positioned on
ON. The lamp flickers and
the display shows 'E1' or
'E2'.
Poor burning and/or lots of
soot is created
The heater does not start
and the lamp is not burning.
Error messages:
E0: No power. Ensure the correct supply of power.
E1 and E2: Contact a qualified technician for repairs.
E3: The thermostat has switch off the device. After cooling down sufficiently, the device will restart
automatically.
Be carefull!
Flames may never exit the air outlet. If there are flames outside the outlet, pump
pressure is too high. Please refer to instruction manual for setting the pump pressure
correctly.
1 – Thermostat is set too low
2 – The electrical connection
of the print plate / motor is
broken
1 – Fuel filter is dirty
2 – Poor quality fuel
1 – Heater is over-heated
2 – The device is not receiving
any power
3 – The fuse is burnt out
4 – Poor electrical connection
between the temperature
limiter
and the print plate
34
1 – Set the thermostat to a higher
temperature
2 – Check all the electrical connections
See wiring diagram
1 – Clean/replace fuel filter
2 – Check whether the fuel is not dirty
or old
1 – Switch the device OFF
for at least 10 minutes and let it cool
down.
Then switch ON the device once
again.
2 – Check the socket, electricity cord
and if necessary, the extension
cord.
3 – Check/replace the fuse
4 – Check all the electrical connections
See wiring diagram