Pump Reassembly; Restart Instructions - Pentair CHALLENGER VS2 Guide D'installation

Masquer les pouces Voir aussi pour CHALLENGER VS2:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42
18

Pump Reassembly

1.
When installing the replacement seal into the seal
plate, use soapy water to wet the rubber boot
before pressing it into the seal plate.
2.
Remount the seal plate to the motor.
3.
Before installing the rotating portion of the seal on
the motor shaft, wet the motor shaft with soapy
water and slide the seal onto the motor shaft.
Ensure that the carbon face contacts the ceramic
face of the stationary seat. Press the seal into
the seal plate with your thumbs and wipe off the
ceramic with a clean cloth.
4.
Screw impeller onto the motor shaft (clockwise to
tighten).
5.
Screw in the impeller lock screw (counter-
clockwise to tighten).
Note: Insert a 1/4" hex Allen wrench into the
motor shaft through the hole in the rear motor
fan cover. This will prevent the motor shaft from
rotating and you screw in the impeller lock screw.
6.
Remount the diffuser onto the seal plate. Make
sure the plastic pins and holding screw inserts
are aligned.
7.
Grease the diffuser quad ring and seal plate
O-ring prior to reassembly.
8.
Assemble the motor sub-assembly to the strainer
pot-pump body. Tighten the bolts until all 4 bolts
are in place and finger tightened.
9.
Fill the pump with water.
10. Reinstall the pump lid and plastic clamp; see the
next section, 'Restart Instructions' .
11. Re-prime the system.

Restart Instructions

If VS2 Variable Speed Pump is installed below the
water level of the pool, close return and suction lines
prior to opening hair and lint pot on pump. Make sure
to re-open valves prior to operating.
Priming the Pump
The pump strainer pot must be filled with water
before the pump is initially started.
Follow these steps to prime the pump:
1.
Remove the pump lid plastic clamp. Remove the
pump lid.
2.
Fill the pump strainer pot with water.
3.
Reassemble the pump cover and plastic clamp
onto the strainer pot. The pump is now ready to
prime.
4.
Open the air release valve on the filter, and stand
clear of the filter.
5.
Turn on the power to the pump.
6.
Press the Start/Stop button on the drive keypad.
If the pump is currently scheduled to run it will
start.
Note: If the pump is not schedule to start, press
a Speed button to begin a manual override that
will start the pump.
7.
When water comes out of the air release valve,
close the valve. The system should now be free
of air and recirculating water to and from the pool.
Whisperflo VS2 Motor Assembly

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Whisperflo vs2

Table des Matières