Pump Reassembly - Pentair STA-RITE DS2 Serie Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MAINTENANCE
3.
Remove rotating half of seal by placing two screw drivers
under seal ring and carefully prying up (Figure 17).
4.
Remove nuts from studs holding seal plate to motor.
Carefully slide seal plate off of shaft.
NOTICE: Be sure you do not scratch or mar shaft. If shaft
is marred, it must be dressed smooth with fine emery or
crocus cloth before installing new seal. DO NOT reduce
shaft diameter!
5.
Place seal plate half face down on flat surface and tap out
stationary half of seal (Figure 18).
Figure 18 – Tap Out Seal
INSTALLING NEW SEAL
Gaskets and o-rings are not interchangeable per models.
Make sure to install the type of gasket or o-ring you removed.
1.
Clean seal cavity in seal plate.
2.
Sparingly wet outer edge of rubber cup on ceramic seat
with liquid soap.
3.
Put clean cardboard washer on seal face. The ceramic
seal's polished face should be facing up. Firmly and
squarely, press ceramic seal into cavity using only hand
pressure.
4.
If seal will not seat correctly:
Remove seal, placing polished side up on bench. Re-
clean cavity and install as outlined in previous step.
If seal still does not seat properly after re-cleaning
the cavity, place a cardboard washer over polished
seal face and carefully press into place using a piece
of standard 3/4 inch pipe as a press being careful not
to scratch seal face."
5.
Dispose of cardboard washer and recheck seal face to
be sure it is free of dirt, foreign particles, scratches and
grease.
6.
Inspect shaft to be sure it is free of nicks and scratches.
7.
Reassemble pump body half to motor flange. BE SURE it
is right side up.
8.
Apply liquid soap sparingly (one drop is sufficient) to
inside diameter of rotating seal member.
9.
Slide rotating seal member (carbon face first) onto shaft
until rubber drive ring hits shaft shoulder.
S30 (11-21-19)
3030 0997
NOTICE: Be sure not to nick or scratch carbon face of seal
when passing it over threaded shaft end or shaft shoulder.
The carbon surface must remain clean or short seal life will
result.
10. Hold motor shaft with 7/16" open end wrench on shaft
flats and screw impeller onto shaft. Be sure you do
not touch capacitor terminals with body or any metal
object. Tightening impeller will automatically locate seal
Figure 19 – Press in New Seal
Be Careful That
Motor Shaft Shoulder...
Ceramic
Face
Figure 20 – Protect Seal Faces
in correct position.
11. Replace impeller screw (if used) by turning
counterclockwise (left-hand thread) into end of shaft.
12. Remount diffuser on seal plate with two screws.
13. Follow instructions under "Pump Reassembly".

PUMP REASSEMBLY

1.
Clean gasket or o-ring surfaces on on both the pump
body and the seal plate. Install new gasket or o-ring per
Installing New Seal" instructions.
2.
Slide motor/seal plate assembly into pump body. Secure
with capscrews.
3.
Replace base mounting bolts.
4.
Replace motor wiring; close draincock.
5.
Prime pump according to instructions. See "Opera tion."
6.
Check for leaks.
3031 0997
...Does Not Damage
Seal Face
Carbon
Face
1072 0697
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sta-rite ds2heSta-rite ds2hfSta-rite ds2hgSta-rite ds2hhg

Table des Matières