Custom Schedules - Pentair CHALLENGER VS2 Guide D'installation

Masquer les pouces Voir aussi pour CHALLENGER VS2:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42
11
SPEED 1 is set to begin at 8:00am and run at 3000
RPM for a duration of 2 hours. When SPEED 1 is
complete the pump immediately begins running the
default SPEED 2. SPEED 2 is factory default to 1400
RPM and will last for 10 hours. When SPEED 2 has
completed its run the pump will run SPEED 3 at 2200
RPM for a duration of two hours.
After 14 hours of run time and completing its run of
SPEED 3, the pump will enter a stationary/paused
state for the next 10 hours. The pump will restart at
8:00am the next morning and cycle through the default
schedule again. The pump will continue to run in this
in this manner until a custom schedule is programmed
into the drive by the user.
Note: The Start/Stop button must be pressed, and the
LED lit, for the pump to run.

Custom Schedules

To customize the run schedule for your VS2 Variable
Speed Pump, the pump must be stopped. Be sure that
the Start/Stop button LED is not illuminated.
Programming a Custom Schedule:
Note: When programming, the LED light next to the
parameter ("Speed", "Time" and "Duration") you are
setting will blink.
1.
Stop the pump if it is running by pressing the Start/
Stop button.
2.
Press the "1" button. The LED above the selected
SPEED will begin to blink and the "Speed"
parameter LED will blink while editing. See
Figure 8.
3000
Figure 8: Setting Speed
3.
Use the "+" and "-" arrows to adjust the speed in
RPM for SPEED 1.
Note: Speed is adjusted up or down by increments
of 10 RPM.
4.
Press the "1" button again and the display will
change to SPEED 1 star t time. The " Time"
parameter LED will begin to blink. See Figure 9.
8 : 00
AM
Figure 9: Setting Start Time
5.
Use the "+" and "-" arrows to adjust the daily start
time for SPEED 1.
6.
Press the "1" button again and the display will change
to SPEED 1 duration. The "Duration" parameter LED
will begin to blink. See Figure 10.
2 : 00
Figure 10: Setting Duration
7.
Use the "+" and "-" arrows to adjust the duration for
SPEED 1 in hours and minutes.
Note: The duration parameter is adjusted in 15 minute
increments.
8.
Pressing the "1" button will continue to cycle through
these parameters, but the changes are immediately
saved as they are adjusted.
9.
Press the "2" button. The LED above SPEED 2 will
begin to flash and the corresponding parameter LED
will flash while editing.
10. Use the "+" and "-" arrows to adjust the speed in
RPM for SPEED 2.
11. Press the "2" button again and the display will change
to SPEED 2 duration.
Note: SPEEDs 2 and 3 do not have a start time,
as they begin their duration immediately after the
previous SPEED finishes.
12. Use the "+" and "-" arrows to adjust the duration for
SPEED 2 in hours and minutes.
13. Repeat steps 9-12 to program SPEED 3 and QUICK
CLEAN.
Note: Remember that the duration allowed for SPEED
3 will be limited to the remaining time in a 24 hour
day. Any time in the 24 hour day not programmed
into SPEEDs 1-3, the pump will remain in a stationary
state.
[ SPEED 1 + SPEED 2 + SPEED 3 < 24 Hours ]

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Whisperflo vs2

Table des Matières