Quick Clean

The VS2 Variable Speed Pump is equipped with a Quick Clean
feature, which can be engaged to temporarily run at higher or
lower speeds ranging between 300 to 3450 RPM. Once the
Quick Clean duration has elapsed, the pump will automatically
return to the programmed schedule.
Programming Quick Clean:
1.
Stop the pump if it is running by pressing the
Start/Stop button.
2.
Press the Quick Clean button. The LED
above the Quick Clean button and the "Speed"
parameter LED will flash while editing. See
Figure 12.
3450
Figure 12: Setting Speed for Quick Clean
3.
Use the "+" and "-" arrows to adjust the speed in
RPM for Quick Clean.
4.
Press the Quick Clean button again and the
display will change to Quick Clean duration. The
"Duration" parameter LED will flash while editing.
See Figure 13.
Note: The Quick Clean feature does not have a
start time.
2 : 00
Figure 13: Setting Duration for Quick Clean
5.
Use the "+" and "-" arrows to adjust the duration
in hours and minutes for Quick Clean.
6.
Press the Start/Stop button and ensure the LED
is illuminated. The pump is now on and will run
the speed and duration set for Quick Clean.
Note: When the Quick Clean duration ends, the pump resumes
the 24 hour schedule at the point where it normally would be
running at that time. The Quick Clean duration will not affect
the start or stop times of the 24 hour schedule. For example, if
Quick Clean runs during a period overlapping with a later part of
SPEED 1 and an early part of SPEED 2, the start time of SPEED
3 is not affected.
Note: Pressing/Holding Quick Clean key for more than three (3)
seconds will cancel Quick Clean mode.
Note: During the Quick Clean mode, the pump will not start with
the priming sequence.
Note: It is recommended that you do not set the Quick Clean
duration to 0 HRS. Setting the Quick Clean duration to 0 HRS
will not allow you to change the duration setting while the motor
is running. The motor will have to be stopped in order to change
the Quick Clean settings if the duration is set to 0 HRS.

Keypad Lockout

Key lockout will not prevent the motor from being stopped by pressing
the Start/Stop button. It will then be unable to be restarted until the
keypad has been unlocked. If the motor is operating in Keypad Lockout
mode, and being controlled through external controls, it can only run
when the Start/Stop LED is illuminated.
The VS2 Variable Speed Pump user interface has a Keypad Lockout
feature to prevent unwanted changes to the settings. When locked,
the keypad will only accept input from pressing the Display button
to cycle the displayed information on the screen and input to stop
the motor from a press of Start/Stop button.
The keypad can be locked by pressing and holding the "1" button
and the Quick Clean button at the same time for at least three
seconds. "Loc On" will be displayed if successful.
To unlock the keypad press and hold the "1" button and the Quick
Clean button at the same time for at least three seconds. "Loc OFF"
will be displayed if successful.
Note: While operating in Keypad Lockout mode the motor can still
be stopped by pressing the Start/Stop button. However, the motor
can not be started again until the user unlocks the keypad.