Balluff BOD 21M-LBI05-S4 Notice D'utilisation page 44

Capteur de distance laser avec io-link et fonctions additionnelles
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Photoelectric Sensors
Laser distance sensor with IO-Link and additional functions
BOD 21M-LBI05-S4
Technical data
Optical
Function principle
Working range
Measuring range
Setting range for switching
output (background
suppression)
Resolution
30...170 mm
170...200 mm
Light type
Laser class
per EN 60825-1:2014
Wavelength λ
Pulse duration t
i
Laser power P
average
Beam characteristic
Light spot diameter
at 30 mm
at 200 mm
Switching distance deviation
20 % at 90 % remission
5 % at 90 % remission
Reference material
Switching hysteresis
Mechanical
Connection type
Housing material
Sensing surface material
Housing dimensions
Weight
Environmental conditions
Ambient temperature T
a
Degree of protection per
IEC 60529
Ambient light
20
english
Laser distance sensor with
background suppression
30...200 mm
170 mm
35...200 mm
10 μm typ.
100 μm typ.
Laser, red light
1
655 nm
2...100 μs
260 μW
Focus at 400 mm
1 × 3 mm
0.5 × 1.5 mm
1 % at s
(typ.)
r
4 % at s
(typ.)
r
White, 90 % remission,
100 × 100 mm
100...10000 μm
M12 male, 4-pin
GD-Zn
Glass
51 × 42.5 × 15 mm
≤ 80 g
–10...+70 °C
IP67
≤ 10 kLux
Electrical
Operating voltage U
B
Rated operating voltage U
e
Ripple (% of U
)
e
No-load supply current I
at U
0
Rated operating current I
e
for switching output
Load capacity at U
e
Voltage drop U
at l
d
e
Time delay before availability
Turn-on time
Turn-off time
Switching frequency f
(at U
max
Counting frequency
Measuring frequency
Analog output
Load resistance, analog output
1)
Non-linearity
30...170 mm
170...200 mm
Measuring accuracy, absolute
30...170 mm
170...200 mm
Temperature drift
1)
Repeat accuracy
Switching output
Digital input
Switching logic
Short-circuit protection
Polarity reversal protected
Protection class
1)
at 20 °C ambient temperature
IO-Link
Vendor ID
Device ID
IO-Link version
Transmission rate
Minimum cycle time
Operating voltage
Counting frequency
15...30 V DC
24 V DC
≤ 10%
≤ 40 mA
e
100 mA
≤ 0.11 µF
≤ 1 V
50 ms
2 ms
2 ms
)
250 Hz (SIO mode)
e
250 Hz (SIO mode)
500 Hz (corresponds to
a measuring time of
2 ms)
4...20 mA
< 500 Ohm
±1.5 mm max.
±3 mm max.
1)
±1 mm max.
±3 mm max.
0.1 %/K FS
±0.25 mm max.
PNP, NPN, Push-Pull
configurable
Reset input, high-active
Normally open,
normally closed
configurable
yes
yes
2
0x0378 (888)
0x031005 (200709)
V1.1
38.4 kbps (COM2)
6.4 ms
18 to 30 V DC
Depends on the cycle
time

Publicité

Table des Matières
loading