Photoelectric Sensors
Laser distance sensor with IO-Link and additional functions
BOD 21M-LBI05-S4
IO-Link interface (continued)
System commands
Index
Name
(dec)
0x0002
System
(2)
Command
18
english
Data
Access
Value range
format
UINT8
W
0x01 (1) =
ParamUploadStart
0x02 (2) =
ParamUploadEnd
0x03 (3) =
ParamDownloadStart
0x04 (4) =
ParamDownloadEnd
0x05 (5) =
ParamDownloadStore
0x06 (6) =
ParamBreak
0x40 (64) =
Teach Apply
0x41 (65) =
SP1SingleValueTeach
0x42 (66) =
SP2SingleValueTeach
0x4F (79) =
Teach Cancel
0x80 (128) =
Device Reset
0x82 (130) =
Restore Factory Settings
0xA2 (162) =
SSC Reset
0xA5 (165) =
Reset Operating Hours
0xA6 (166) =
Reset Counter
0xA7 (167) =
Statistic Reset
0xA8 (168) =
Statistic Start
0xA9 (169) =
Statistic End
0xE1 (225) =
Teach Measurement
Range Lower Limit
0xE2 (226) =
Teach Measurement
Range Upper Limit
Remarks
Block
Start Parameter Upload
Parameteri-
zation
Stop Parameter Upload
Start Parameter Download
Stop Parameter Download
Stop block parameter download
and set Upload Request
Cancel block parameterizing
Teach
Save and apply switch point
Channel
Teach TP1 of SP1
Teach TP1 of SP2
Cancel Teach-In
Reset
Reset device
Reset sensor parameters to
factory defaults
Set SSC (addressed by Teach-In
channel) to factory defaults
Reset individual operating hours
counter to 0
Reset counter value
Statistic
Reset statistics recording
Start statistics recording
End statistics recording
Teach
Teach start position
analog
Teach end position