Balluff BOD 21M-LBI05-S4 Notice D'utilisation page 16

Capteur de distance laser avec io-link et fonctions additionnelles
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Optoelektronische Sensoren
Laser-Distanzsensor mit IO-Link und Zusatzfunktionen
BOD 21M-LBI05-S4
IO-Link-Interface (Fortsetzung)
Device-spezifische Parameter
Index
Name
Subindex
(dez)
0x0057
Operating
(87)
Hours
0x00B4
SIO Output
(180)
Type
0x00B5
SIO Output
(181)
Function
0x00B6
Switch
(182)
Counter
Settings
0x00B7
Switch
(183)
Counter
State
0x00B8
Time Delay
(184)
Function
Q1
(Pin 4)
0x00B9
Time Delay
(185)
Function
Q2 (Pin 2)
0x00BA
Debounce
(186)
Time
14
deutsch
Name
(dez)
0x01 (1)
Operating
Hours
0x02 (2)
Operating
Hours
Individual
0x01 (1)
Q1
0x02 (2)
Q2/Iout
0x01 (1)
Unused
0x02 (2)
Iout
0x01 (1)
Mode
0x02 (2)
Limit
0x03 (3)
Unused
0x04 (4)
StartupDelay
0x01 (1)
Status
0x02 (2)
Counter
0x01 (1)
Delay Function
Mode
0x02 (2)
Delay Time 1
(On delay)
0x03 (3)
Delay Time 2
(Off delay,
One shot)
0x01 (1)
Delay Function
Mode
0x02 (2)
Delay Time 1
(On delay)
0x03 (3)
Delay Time 2
(Off delay,
One shot)
0x01 (1)
Pin 4
0x02 (2)
Pin 2
Daten -
Zugriff
Wertebereich
format
UINT32
R
UINT8
R/W
0x01 (1) = PNP
0x02 (2) = NPN
0x03 (3) = PushPull
0x01 (1) = PNP
0x02 (2) = NPN
0x03 (3) = PushPull
0x05 (5) = Analog Output
4...20 mA
UINT8
R/W
0x00 (0)
0x00 (0) = Rising
Characteristics
0x01 (1) = Falling
Characteristics
UINT8
R/W
0x00 (0) = Off
0x01 (1) = Counter Static
0x02 (2) = Counter Auto
UINT16
0x0001...0xFFFF (1...65535)
UINT16
0
UINT8
0x00...0xFF (0...255)
UINT8
R
Bit 0 = Count Limit OK
Bit 1 = Count Limit Too Low
Bit 2 = Count Limit Too High
UINT16
UINT8
R/W
0x00 (0) = Delay
0x01 (1) = One shot
UINT16
R/W
0x0000...0xFFFF (0...65535)
0 = Timing Function off
UINT16
R/W
0x0000...0xFFFF (0...65535)
0 = Timing Function off
UINT8
R/W
0x00 (0) = Delay
0x01 (1) = One shot
UINT16
R/W
0x0000...0xFFFF (0...65535)
0 = Timing Function off
UINT16
R/W
0x0000...0xFFFF (0...65535)
0 = Timing Function off
UINT16
R/W
0 = Timing Function off
0x0000...0xFFFF (0...65535)
0 = Timing Function off
Bemerkung
Betriebsstunden-
zähler (Stunden)
Kann über Sys-
temkommando
Reset Operating
Hours zurückge-
setzt werden
Im SIO-Modus
Im SIO-Modus
Sekunden
Millisekunden
Millisekunden
Millisekunden
Millisekunden
Entprellzeit
Reseteingang
(Millisekunden)

Publicité

Table des Matières
loading

Table des Matières