Balluff BOD 21M-LBI05-S4 Notice D'utilisation page 41

Capteur de distance laser avec io-link et fonctions additionnelles
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Photoelectric Sensors
Laser distance sensor with IO-Link and additional functions
BOD 21M-LBI05-S4
IO-Link interface (continued)
Diagnostic parameters
Index
Name
(dec)
0x0024
Device
(36)
Status
0x0025
Detailed
(37)
Device
Status
0x0028
Process
(40)
Data Input
0x0029
Process
(41)
Data Output
Events
Event code
Meaning
0x4210
Excess
Temperature
0x5011
Data Loss
0x5111
Undervoltage
0x7710
Short Circuit
0x8CA0
Parameter
Changed
0x8DB0
Teach Timeout
0xFF91
Upload Request
www.balluff.com
Subindex
Data format
(dec)
0x00 (0)
UINT8
0x00 (0)
ArrayT of
OctetStringT3
0x00 (0)
UINT40
0x00 (0)
UINT8
Mode
Type
appears/
Warning
disappears
appears/
Error
disappears
appears/
Warning
disappears
appears/
Warning
disappears
One-time
Message
One-time
Message
One-time
Message
Access
Value range
R
0x00 (0) = Device OK
0x01 (1) =
Maintenance-Required
0x02 (2) =
Out-of-Specification
0x03 (3) = Functional-Check
0x04 (4) = Failure
R
R
R
Device Status
Out-of-Specification
Failure
Out-of-Specification
Out-of-Specification
OK
OK
OK
Remarks
Not used
Implemented as
dynamic list. See
Events with
Mode appears/
disappears.
See Process
Data Output Data
See Process
Data Input Data
Remarks
Supply voltage < 18 V in
IO-Link mode
When parameter settings are
lost. Sensor continues to
operate using factory
defaults.
Teach-In enabled > 10 min
After local parameterization
and system command
ParamDownloadStore