Laser distance sensor with IO-Link and additional functions
BOD 21M-LBI05-S4
Sensor function principle and Teach-In of the
switchpoints through IO-Link
The sensor supports two sensor function principles. The
IO-Link parameter 0x00BB can be used to toggle between
background suppression and background evaluation.
A static Teach-In procedure in Single Value Teach is used
for teaching the switchpoints. In parameter 0x003B
Teach-In status the current status of the Teach-In
procedure is indicated.
Teach flags
SP2
SP1
TP1
TP1
Example for:
0 = IDLE
0 = TP1 for SP2 not
1 = SP1 SUCCESS
taught or not successful
2 = SP2 SUCCESS
3 = SP12 SUCCESS
1 = TP1 for SP2
4 = WAIT FOR COMMAND
successfully taught
5 = BUSY
6 = reserved
7 = ERROR
Tab. 2: Teach-In Status
Sensor principle: background suppression
The object is taught.
SP1
TP1
Fig. 9:
Single Point Mode background suppression
www.balluff.com
Teach state
Sensor function principle and Teach-In of the
switchpoints through IO-Link (continued)
Teach-In background suppression Single Point Mode
The switchpoint can also be taught in SIO mode
using the button (see page 4).
If the Teach-In procedure is not completed, it
will be automatically canceled after 10 min. and
all the original settings are retained.
Teaching switchpoint in IO-Link mode:
1. Position the object in the beam path.
2. Select Teach-In channel:
Access
Index
Value
W
0x003A
0x00
W
0x003A
0x01
W
0x003A
0x02
3. Teach point (TP1 for SP1). Send system
command 0x41 to sensor.
Access
Index
Value
W
0x0002
0x41
If the red LED comes on, TP1 could not be taught
(alignment is unsuitable or the object is outside the
detection range).
4. Verify whether TP1 has been taught successfully:
Read out and check the parameter Teach-In Status
using Index 0x003B.
Access
Index
Value
R
0x003B
0x14
0x07
5. Save and apply switch point SP1:
Send system command 0x40 to sensor.
Access
Index
Value
W
0x0002
0x40
Meaning
Standard SSC1
SSC1
SSC2
Meaning
SP1 Single Value
Teach
Meaning
Result
TP1 was
Go to
successfully
step 5