Should the flame go out during operation, immediate re-
ignition takes place within the closing time of the safety pilot
(approx. 30 seconds).
If a flame is not produced, the auto ignitor continues to work
until "0" is switched on the control knob (a).
10
Battery change on the auto ignitor
If ignition sparks cannot be heard when commissioning or
only at intervals of more than one second, the battery needs
to be replaced.
Only change the battery with the heating system switched off.
Insert a new battery before the beginning of each heating sea-
son! Dispose of the old battery correctly!
Only use temperature-resistant (+70 °C), leak-proof mignon
batteries (LR 6, AA, AM 3) (part no. 30030-99200); other bat-
teries can cause function faults!
Remove cover (see installation instructions), push the battery
compartment cover upwards and replace the battery. Pay at-
tention to positive / negative. Close the battery compartment
again (see installation instructions).