▷ Position the crown in the blank in
such a manner that the clearance
E N
from the crown margin to the blank
surface is at least 1 mm.
This ensures that the crown has no
contact to the sinter skin of the blank.
Procedure when fabricating dental framework
The determined enlargement factor for the blanks is provided on the
blanks.
▷ Enter the enlargement factor in the CAM software.
▷ Mill the blanks applying the milling strategies provided for the mate-
rial.
▷ Clean the frames from residual zirconia dust using a brush or com-
pressed air.
32
When processing the blanks in the milling machine, it is recom-
mended to use only mills, whose service life is still in the green
range of the wear indication.
Further details on designing and manufacturing framework
with the Ceramill Mind CAD software are available on the
Ceramill M-Center homepage in the protected download area.
>1 mm