A P P L I C A T I O N
Material-specific frame parameters
The following material-specific frame parameters must be complied
E N
with when fabricating zirconium oxide frames in high-density sintered
condition:
Ceramill
Zolid FX ML
Detailed minimum wall thicknesses and connector cross-sections
Indication
Primary
components/
Double
crowns
Single crown
Front-tooth
bridge
Posterior
bridge
O Abutment crown
X Bridge unit
30
Minimum
Connector cross-
frame thick-
ness
in mm
Anterior
≥ 12
0.5
Total
number
Pattern
of units
–
1
–
1
OXO
3
OXO
3
2
section in mm
Posterior
≥ 12
Wall thickness
Number of
connected
bridge
incisal/
units
occlusal
–
0.7
–
0.5
1
0.5
1
0.7
Maximum number of
connected bridge
units
Anterior
Posterior
1
1
Connec-
in mm
tor
cross-
section
circular
in mm
–
0.5
–
0.5
≥ 12
0.5
≥ 12
0.5
2