SIMPLE LOGGER II
MODEL
Electrical
Channels
Input
Input Level
Maximum Input Voltage***
Input Impedance
Sample Rate
Storage Rate
Storage Mode
Recording Length
Memory
Communication
Power Source**
Battery Life
Mechanical
Dimensions
Weight (with battery)
Case
Vibration
Shock
Drop
Environmental
Operating Temperature
Storage Temperature
Relative Humidity
Altitude
Safety & Electro-magnetic compatibility
Safety Rating
Protection Degree
CE Approved
*See the end of chapter
(1) This recording mode stores the time and duration of the event, and the channel the event occurred on.
An event occurs when the input falls below 0.7 V and ends when it rises above 0.8 V. An internal pull up is
provided for contact closure.
One 8-position removable screw-type terminal block
Contact closure, 0 to 5 V
Maximum of 8 per second
Maximum once every two sample periods (event dependent)
15 minutes to 8 weeks, programmable using DataView
50,000 events (512KB).Recorded data is stored in non-volatile memory
andretained even if battery is low or removed.
USB 2.0 optically isolated
2 x 1.5 V AA (LR6) alkaline batteries
100 hours to > 45 days(dependent on storage rate/recording length)
5.45 x 2.75 x 1.28" (136 x 70 x 32 mm)
Polycarbonate UL94-V0
IEC 68-2-6 (1.5 mm, 10 to 55 Hz)
14° to 122°F (-10° to 50°C)
-4° to 140°F (-20° to 60°C)
Up to 85% at 95°F (35°C), Non-condensing
EN 61010-1; 50 V CAT III; Pollution Degree 2
L404
Four
10 V
DC
>150 kΩ
Event Recording(1)
6.4 oz (181 g)
IEC 68-2-27 (30 G)
IEC 68-2-32 (1 m)
2000 m
IP40
Yes
English
®
Page 51