Initial Operation - Gardena 6000/3 S Mode D'emploi

Masquer les pouces Voir aussi pour 6000/3 S:
Table des Matières

Publicité

a circuit breaker safety switch with rated fault
current of ≤ 30 mA. Furthermore, installation
regulations according to DIN VDE 0100-702
have to be observed.
➔ Please contact your electrician.
In Austria, according to ÖVE B/EN 60 555 part
1 to 3, pumps which are used in swimming
pools and garden ponds, and equipped with
firm power cable should be fed via an ÖVE
approved isolating transformer – rated voltage
must not exceed 230 V.
Power cables must not have a smaller dia-
meter than rubber sheathed cables described
with letter symbols H07 RNF according to DIN
VDE 0620. Length should be 10 metres.
When connecting the pump to the water sup-
ply system, the country-specific sanitary regu-
lations must be observed to prevent water not
of drinking water quality being drawn back in.
➔ Please consult a specialist for sanitary
installations.
The power cable of the Submersible Pressure
Pump must be connected to a socket which is
positioned at a height of max. 1.10 m (measu-
red from ground). Take care that the power
cable leads downwards.
Always check the pump (above all power cable
and plug) before each operation. A damaged
pump must not be used. It's imperative to have
the damaged pump checked by one of the
listed GARDENA Service Centres.
Take care that the electrical connections are
made within dry area, protected from flooding.

3. Initial Operation

Hose Connection:
©
©
©
©
➔ Screw the supplied pump fitting
and tighten it manually until the washer fits closely..
If necessary the 33.3 mm (G1) female thread at the output of the
©
pump can be converted to a male thread by attaching the
GARDENA Pump Fitting
©
The pump can then be connected to the GARDENA hose
connection system and the GARDENA Suction Hose Fitting
Art. 1723 / 1724.
Best results in delivery capacity of the pump are achieved when
using 19 mm (3/4") hoses in conjunction with GARDENA "Profi"
Maxi-Flow System fittings (e.g. Art. 1752) or 25 mm (1") hoses
with fittings available at your sanitary dealer.
When connecting simultaneously several hoses/accessories, we
recommend to use either our GARDENA Twin-Tap Connector or
our Four Channel Water Distributor (Art. 1210/1194) which can be
directly screwed onto the pump fitting
©
Protect plug and power cable from heat, oil
and sharp edges.
Check line voltage. Data Indicated on the type
plate must match technical data of the mains
supply.
Children under the age of 16 are not allowed to
operate the pump. Keep them away from the
connected unit.
Before use, first clear the outlet line (e.g. open
the nozzle).
Observe max. delivery height (see point 7).
Dry-running operation absolutely
must be avoided, i.e. the pump
should only be started in the water.
The pump must be immediately
switched off when water fails to flow. Please
observe that the pump always have to be
submerged at least 20 cm in water during
operation.
The pump is automatically switched off on
overheating by the integrated thermal motor
protector. After having cooled down, the motor
switches on again automatically.
In order to unplug, pull the plug shell not the
power cable.
The power cable must not be used for mount-
ing or relocating the pump. For submerging or
lifting/securing the pump, please use the supp-
lied fastening rope.
Sand and other abrasive material cause increa-
sed wear and reduce the pump's output.
Avoid running the pump for more than 10 min.
against closed delivery side.
onto the outlet of the pump
, Art. 1745 supplied with the pump.
.
9