Front view
(1)
(1) Power switch
(2) LC-Display
(3) Master-Reset-button. If this button is pressed, the manufacturer specific parameters (average adjustments) are loaded. They guarantee a system
operation even if the user carries out an incorrect adjustment. As the Master-Reset-button is countersunk use a pen or something like that
for pressing.
Two multi-function buttons:
(4) Left button "Reset" pressed alone for approximately 12 seconds resets all adjustable parameters to user specific adjustments (refer to
chapter 5.3).
(5) Right button "N.o.m." pressed alone shows the maximum number of switchable delegate microphone units for approximately 10 seconds.
Configuration
Max
NOM 2
Reset
(6) Serviceport, RS 232 interface for system configuration with the MCS-Editor via PC
Rear view
(7)
(8)
(7) Audio output: 3-pin XLR output for the connection of amplifiers, mixing consoles etc.
(8) Input, 3-pin XLR, balanced (250 mV)
(9) Extension input, 3-pin XLR, unbalanced (1,55 V)
(10) Record: Connection to record documentations (250 mV)
(11) Microphones Line 1, 15-pin Sub-D socket
(12) Microphones Line 2, 15-pin Sub-D socket (MCS 50/64 version only!)
(13) RS 232 for the connection of an operator's PC (operation via mouse or touchscreen) or other available conference systems such as AMX
Crestron
®
. Use a standard RS 232 cable, straight, (female - male).
(14) Mains
34
(2)
N.o.m.
(9) (10)
(11)
(4)
(3)
(5)
(12)
(13)
(6)
(14)
®
,