PAY ATTENTION!! THE SEALING BAR START WORKING ON THE AUTOMATIC
MODELS
Line Salvaspesa:
The red led lights: the machine works correctly
The red led doesn't lights: internal problem on pipe or vacuum pumps
Line Family and de Luxe Inox:
The meter gauge arrive on red: the machine works correctly
The meter gauge remains on jellow or on green: problem on the electro valve
The meter gauge don't move: internal problem on pipe or vacuum pumps
WELDING BAR TEST
The welding is not regular or there are some points not sealed: verify the bag is clean and
dry ( if the bag is wet or greased, the seal cannot be done correctly).
The vacuum is loose after few days in a bag under vacuum: it is a tipical bag problem with
little holes; the machine works correctly.
QUESTIONS / ANSWERS
In case of doubts about the correct functioning of the appliance, some test can be done by then user
to verify the performances of the machine.
Internal functioning:
1-
Open the cover and start the cycle once blocked the air suction plug Image 6
2-
If the manometer arrive on red ( or the red led light on ) and the seal start automatically,
inside the machine all is good.
3-
If the manometer arrive on red ( or the red led light on ) but the seal do not start
automatically, set the unit on automatic cycle and re-test
4-
If the manometer do not arrive on red ( or the red led do not light on ), the machine must be
repaired
Cover and vacuum gasket functioning:
1-
Close the cover ( without bag) and press pump switch ( 1 ) to start the cycle, slightly press
with both hands the cover. Image 7
2-
If the manometer arrive on red ( or the red led light on ) and the seal start automatically, the
machine is good.
3-
If the manometer arrive on red ( or the red led light on ) but the seal do not start
automatically, set the unit on automatic cycle and re-test
4-
If the manometer do not arrive on red ( or the red led do not light on ), pls check the vacuum
chamber gasket, clean or replace and re-test
Bag test:
1-
Open the cover
2-
Place the open side of an empty vacuum bag in the vacuum chamber , between the
gaskets . Image 1
3-
Close the cover and press pump switch ( 1 ). This will start vacuum operation.
4-
As soon as vacuum pump starting, slightly press with both hands the cover so as it sticks to
the surface of the bag. After a few seconds the depression created by the pump will permit
to release the cover, while the machine will keep on suction
5-
If the manometer arrive on red ( or the red led light on ) and the seal start automatically, the
machine is good.
6-
If the manometer arrive on red ( or the red led light on ) but the seal do not start
automatically, set the unit on automatic cycle and re-test
110