INDICATIONS ON THE DISPLAY (D1, page 18)
Start up display (shown for 2 seconds:)
"GL124E" = ECU model; firmware version "_13"
Indicates the dip-switch setting
memorization stage and firmware version
Alarm indications
System not programmed
You have to enter the programming mode to program the system
Out of position
During normal operation it indicates that the repositioning procedure
must be carried out (see page 19). In this case any commands received
(TA, TC or TD) will automatically start this procedure.
Memory parameter error
Continue programming the system and if the indication persists reset
the electronic programmer after having disconnected the batteries and
switching off the power at the mains. If the error persists contact the
after sales service persists.
Block during encoder programming
This happens when an N.C. contact is activated (FTCI, FTCS/CSP)
during encoder programming or repositioning. Once the passive state
of the security devices has been reset the door will start moving again
automatically. It also happens if a blackout occurs during programming.
Encoder count error
This happens when the programmer sends a command to the motor but
movement is not detected. If the motor begins to move it means there
is a problem with the encoder signal. Check the connections and carry
out repositioning. If the motor doesn't move check the connections for
each motor and the condition of the fuses "F2" and "F4" then carry out
repositioning. If the motor still doesn't work you may have a mechanical
or electronic problem.
Operational indications
Pause time programming
Automatic programming under way
Opening stage
Block
Pause for automatic reclosing (if activated)
Closing stage
Current sensor updating
(only during programming)
Opening + compensation sensor
Closing + compensation sensor
Test mode
Battery mode with a fully charged battery
Battery mode with an undercharged battery
Block caused by a completely flat battery