Installing S4

5.2
Using the reinforcing rails
Supplementary to fig. 3
➤ Before installation, check whether the wall hole needs reinforcing.
➤ Remove the foam/insulation according to the width of your reinforcing
rails (not in scope of delivery) (A).
➤ Fit the reinforcing rails (B).
6
Installing S4
Supplementary to fig. 4
The scope of delivery includes a inner frame which is suitable for a wall thick-
ness of 26 mm. For wall thicknesses of under 26 mm, you must put the inner
frame underneath. For wall thicknesses of 27 – 53 mm, you must place the
spacer strips between the inner and outer frames.
➤ Measure the wall thickness W.
Supplementary to fig. 5 A: Wall thicknesses of 1 – 25 mm:
I
NOTE
For wall thicknesses of 1 – 26 mm, use the 3.9 x 25 mm fastening
screws included in the scope of delivery.
➤ Glue a base to the inner frame referring to the table below:
Wall thickness
1 – 2 mm
3 – 4 mm
5 – 6 mm
7 – 8 mm
9 – 10 mm
11 – 12 mm
13 – 14 mm
6
Height of the
base
25 mm
23 mm
21 mm
19 mm
17 mm
15 mm
13 mm
Wall thickness
15 – 16 mm
17 – 18 mm
19 – 20 mm
21 – 22 mm
23 – 24 mm
25 mm
26 mm
S4
Height of the
base
11 mm
9 mm
7 mm
5 mm
3 mm
1 mm