Cold Weather Installations; Makeup Air; Venting Methods - Whirlpool UVL5430JSS Instructions D'installation Et Guide D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Cold weather installations

An additional back draft damper should be installed to minimize
to minimize conduction of outside temperatures as part of the
vent system. The damper should be on the cold air side of the
thermal break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.

Makeup air

Local building codes may require the use of makeup air systems

Venting Methods

This range hood is factory set for venting through the roof or
through the wall.
The vent system needed for installation is not included.
Roof Venting
A
A. 6" (15.2 cm) vent
through the roof
B. Roof cap
Calculate Vent System Length
The recommended vent system is 6" (15.2 cm) round vent with a
maximum length of 35 ft (10.7 m). For the best performance, use
no more than three 90° elbows.
To calculate the length of the system, add the equivalent feet
(meters) for each of the vent pieces used in the system.
Vent Piece
6" (15.2 cm)
45° elbow
2.5 ft (0.8 m)
90° elbow
5.0 ft (1.5 m)
6
Wall Venting
B
A
B
A. 6" (15.2 cm) vent
through the wall
B. Wall cap
Example vent system: 6" (15.2 cm)
90˚ elbow
3 ft
(0.93 m)
Maximum Length
1 - 90° elbow
1 - wall cap
9 ft (2.8 m) straight
System length
Non-Vented (recirculating) Installations Through the
Soffit/Cabinet
If it is not possible to vent cooking fumes and vapors to
the outside, the range hood can be used in the non-vented
Kit, See the "Assistance or Service" section to order.
Through Cabinet
A
G
B
D
F
E
H
A. Ceiling
B. Vent cover
C.
D. 6" (15.2 cm) vent
E. Range hood
NOTE:
Wall cap
6 ft (1.8 m)
= 35 ft (10.7 m)
= 5 ft (1.5 m)
= 0 ft (0 m)
= 9 ft (2.8 m)
= 14 ft (4.3 m)
Through Soffit
G
F
I
F. Cabinet
G. Wall
H. 12" (30.5 cm) min.
I. 17" (43.2 cm) min.
A
B
C
D
E