1

Safety Guidelines

1.
Follow the installation instructions.
2.
Use the appliance
• according to its intended use
• in good condition
• with due regard to safety and risk of danger.
3.
Note that the appliance is exclusively for use in the
applications detailed in these installation instructions
(see 2 Technical Data). Any other use will not be
considered to comply with requirements and would
invalidate the warranty.
4.
Please take note that any assembly, commissioning,
servicing and adjustment work may only be carried
out by authorized persons.
5.
Immediately rectify any malfunctions which may
influence safety.
2

Technical Data

2.1 SG160S
For closed water heaters in compliance with DIN 4753-1 and
EN 806-2/1988-200.
Media
Medium:
Connections/Sizes
Connection size:
Pressure values
Opening pressure:
Max. operating pressure:
Operating temperatures
Max. operating temperature
medium:
Specifications
Installation position:
* Subsequent alteration of the setting is not permitted and is
impossible without destroying the security cap
2.2 SG160SD
For closed water heaters in compliance with DIN 4753-1 and
EN 806-2
Media
Medium:
Connections/Sizes
Connection size:
Pressure values
Max. inlet pressure:
Outlet pressure:
MU1H-1346GE23 R0420
Drinking water
1
/
" - 1"
2
6, 8 or 10 bar*
Maximum at least below
20 % opening pressure of
safety
40 °C
Horizontal and vertical
Drinking water
1
3
/
",
/
", 1"
2
4
16 bar
1.5 - 6 bar
GB
Min. pressure drop:
Opening pressure:
Max. operating pressure:
Operating temperatures
Max. operating temperature
medium:
Specifications
Installation position:
* Subsequent alteration of the setting is not permitted and is
impossible without destroying the security cap
3

Options

For Options visit homecomfort.resideo.com/europe
4

Assembly

4.1 Installation Guidelines
Safety group must be fitted in the cold water supply to
the hot water storage unit
Horizontal and vertical installation position possible
The installation must be carried out so that:
– There are no shut-off valves or fittings, narrowing
of the pipework or strainers between the water
heater and the safety valve
– Good access is provided for service and
maintenance
– The safety valve is fitted above the top of the water
heater to avoid the need for draining down when
exchanging the safety valve insert
If there is no drainage facility in the room where the
heater is installed, then the safety valve may be fitted
in an adjacent area. EN 806-2 is to be observed
Requires regular maintenance in accordance with
EN 806-5
4.2 Assembly instructions
1.
Blow out or rinse pipe line out well
2.
Install safety group in the cold water line
• Note flow direction
• Install without tension or bending stresses
5

Start-up

5.1 Setting outlet pressure

Set outlet pressure min. 1 bar under inlet pressure.
1.
Close shut-off valve on inlet
2.
Release pressure on outlet side (e.g. through water
tap)
3.
Fit pressure gauge (optional)
4.
Close shut-off valve on outlet
3
1 bar
6, 8 or 10 bar*
Maximum at least below
20 % opening pressure of
safety
40 °C
Horizontal and vertical