Error Diagnosis (Mod.b); Recycling The Product - Fagor EVO-CONCEPT CO-402BDD Instructions D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Machine stops and fills
with water when it is
washing.
The machine does not
start with the wash cycle.
Machine does not drain
completely.
NOTE: If a fault occurs and is not listed in the above table, please call the
technical service. The manufacturer reserves the right to modify the
technical characteristics with prior warning.

6.1 Error diagnosis (MOD.B)

ERROR
DESCRIPTION
1
OPEN DOOR
2
TANK FILL
3
TANK DRAINAGE
4
BOILER HEATING
5
TANK HEATING
6
BOILER FILL

7. RECYCLING THE PRODUCT

The WEEE symbol used for this product indicates that it cannot be treated as domestic waste. Disposing
correctly of the product will help to protect the environment. For further information about the recycling of
these products, please contact the relevant office in your local authority, or the company responsible for
waste disposal or the manufacturer who supplied this product.
To dispose of all or part of the product, directives 2002/95/EC and 2002/96/EC and
successive amendments and/or applicable legislative decrees must be observed. The
manufacturer guarantees the absence of hazardous substances in the EEE used complaint
to directive 2002/95/CE.
In the event of failure to comply with the above, the user will be subject to the penalties
established by each of the member countries of the community.
Cut the electric cable so that it is unusable. Only those plastic parts bearing the recycle
symbol can be recycled.
Pressure switch pipe blocked.
Pressure switch faulty.
Overflow incorrectly mounted.
Door is not closed properly.
Door micro switch faulty.
Machine not levelled correctly.
Pressure switch faulty.
CONSEQUENCE
The ON/OFF LED lights up for 0.5 seconds and then remains unlit for 2 seconds
before lighting up again. This continues as long as the door is open and the
selected cycle is unfinished.
The ON/OFF LED light up twice for 0.5 seconds each time and then remains unlit
for 2 seconds, then lighting up again twice. This continues while the water in the
tank does not reach the correct level in the specified time.
The ON/OFF LED lights up three times for 0.5 seconds each time and then
remains unlit for 2 seconds, then lighting up again three times. This continues
while the drainage pump does not drain the water in the tank to the correct level in
the specified time.
The ON/OFF LED lights up four times for 0.5 seconds each time and then remains
unlit for 2 seconds, then lighting up again four times. This continues while the
water in the boiler does not reach the correct temperature in the specified time.
The ON/OFF LED lights up five times for 0.5 seconds each time and then remains
unlit for 2 seconds, then lighting up again five times. This continues while the water
in the tank does not reach the correct temperature in the specified time.
Le voyant ON/OFF s'allume six fois pendant 0,5 secondes à chaque fois et reste
éteint pendant 2 secondes avant de se rallumer six fois, et ainsi de suite tant que
la chaudière n'a pas atteint le niveau correct dans le temps imparti.
Empty the tub and clean thoroughly.
Call the technical service to replace it.
Mount overflow correctly.
Close the door correctly and if it is seen to re-open
alone, call the technical services to adjust the
tensioneers.
Call the technical service to replace it.
Level the machine In the event of doubt, please
contact your technical service.
Call the technical service to replace the pressure
switch.
41