The air supply opening may not be closed in these cases. The air supply opening must be closable if it is fi tted
in a fi re-retardant wall. If multiple combustion units are fi tted in the same room, then there must be a suffi cient
number of air supply openings to guarantee care-free combustion.
External air supply (optional art. nr. OND.SM.0103)
Any ducting for the supply of fresh outdoor air must have a diameter of 80 millimetres. The air supply duct may be
connected either beneath or at the rear of the stove. If the external air supply runs through a fi re-retardant wall,
then this duct must be closable. If the duct is longer than 1 metre, including a 90-degree bend, then the diameter
of the duct should be increased.
Moulding and fi re surround
Please refer to the instructions supplied with the various mouldings. Take note that, in a number of cases, especially
corner models, it is easier to mount the moulding to the stove before fi tting the stove.
Connecting the stove
The S60/S75 is a medium-heavy (S 60, 80 kg) to heavy (S 75, 100 kg) fi tted wood stove. Make sure beforehand that
the fl oor on which it is to be mounted is strong enough. Before mounting the stove, fi rst follow the instructions in
the previous section 'Preparation' . Protect your back and the fl oor during the entire mounting process.
1. Check the packaging: if there is any visible damage, please report this to us.
2. Remove the stove from the box
3. Remove the baffl e plate from the stove
(see image)
4. Remove the pipe fl ange from the
stove by undoing the 4 screws
5. Place the stove on the desired spot,
ensuring that it is located precisely in
the middle below the fl ue hole
6. Connect the pipe fl ange to the fl ue
duct
7. Remount the baffl e plate in the stove
8. Mount the moulding (take note, in a
number of cases it is easier to fi t the
moulding fi rst)
9. Your stove is now ready to use
GB