EN
Install the product properly according to this installation manual for best performance. When the installation work is
complete, give a detailed explanation of how to use this product to the customer.
Safety Cautions
Read these "Safety Cautions" carefully before starting installation work. Install the product properly.
This manual uses various indications to ensure a proper, safe installation and to prevent injury to the customer,
injury to other people and damage to property.
The symbols should be interpreted as follows.
This symbol indicates the possibility of personal injury and physical damage if the information
Caution
provided is disregarded.
The pictures below are categorized by the following symbols and explained below.
means "Prohibited."
The figure to the left shows "Prohibited."
Do not subject the toilet bowl to strong forces or impacts.
Otherwise, the toilet bowl may break causing injury or leaks that may damaged property.
Do not excessively bend the flexible water supply hose or damage it with a lit cigarette, cutters, etc.
Otherwise, the flexible water supply hose may break causing leaks that may damaged property.
Prohibited
Do not remove the water supply filter with the water supply valve being open.
If the water supply valve is not closed, water may gush out causing leaks that may damaged
property.
Be sure to use the included or specified parts for installation work.
Otherwise, the product may not be installed properly.
Carry out the installation work according to this installation manual.
Required
Otherwise, damage caused by water leaks may occur.
取り付け前のご注意
Precaution before installation
•
Secure the space required for toilet installation and at the same time, check door opening/closing for possible interference.
•
The remote control signal reception may be degraded and the NEOREST unit may not respond to the remote control if
there are shelves or cabinets on the rear wall at a height of less than 55-1/8"(1400 mm) from the floor.
(Shelves and storage cabinets should be more than 55-1/8"(1400 mm)
from the floor.)
•
Turn on electricity and supply water to the product after completing all
installation work.
•
Use care not to damage the end of the connection hose.
•
The minimum required water pressure (dynamic) is 7PSI at 2.64
Gal/min (0.05 MPa at 10 L/min) while the maximum water pressure
(static) is 108PSI(0.75 MPa).
Use the NEOREST within this range.
•
Make sure before installation that the water supply source and water
drain pipe are in the specified positions according to the diagram.
Water supply Rc1/2"
For water supply from the wall
Water supply Rc1/2"
For water supply from the floor
2
(Observe these cautions for safety's sake. )
4-1/2"
(115mm±10mm)
4-1/2"
(115mm±10mm)
12"
(305mm±10mm)
PVC water drain pipe
means a "Required" action you must do.
The figure to the left shows "Required."
Caution
Product Diagram ( Installation completed )
15-5/16"
(389mm)
4-1/2"
(115mm±10mm)
For water supply from the wall
*1 Dimensions showing the space needed for lifting the lid when cleaning.
4-1/2"(115±10mm)
For water supply from the floor
4-1/2"(114mm)( When fully open )
(2-1/8"(54mm)*1)
3-1/2"(88mm)( When fully open )
(1-13/16"(46mm)*1)
27-3/4"(705mm)
(*27-13/16"〜31-7/8"(706mm〜810mm))
24-1/4"
(615mm)
12"
(305mm±10mm)