Servicing; Tighten The V-Belt - Kroll HM200 Notice D'instruction

Masquer les pouces Voir aussi pour HM200:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English

2.8.4 Servicing

According to § 9 of the reglementations for
heating plants it is demanded to let the plant
including the oil burner be serviced regularely in
order to assure a reliable and secure operation of
the device.
A service of the heater is neccessary once a year
We recommended to seal a service-contract with
an authorised entreprise.
Burner After– Sales-Service
The burner should be checked and adjusted
at least annually. On this occasion, the oil filter
insert and the burner jet have to be replaced.
This work must only be made by the After Sales
Service or an authorized specialist firm. After a
failed start attempt, a control and if necessary, a
cleaning of the combustion chamber of unburned
heating oil must take place before the reset but-
ton is pressed again.
Kroll recommends taking out a service contract.
The mobile heating unit must not be modified or
modified or manipulated under no circumstances,
and repair work must be carried out by a specia-
list.
Main filter
Should be exchanged after 200 to 300 operating
hours. Replace the filter insert as soon as water
or dirt is detected in the filterglass.
Fuel oil
Solenoid or water-contaminated fuel oil must be
renewed.

2.8.5 Tighten the V-belt.

Tension of V-belt is ok, if a maximum measure of
15 mm can be hold under light pressure on the
front stretch on the V-belt.
Attention
To avoid damages at the bearings, the V-belt
pulleys have to be in precise alignment!
Maximum misalignment: 1 mm!
Attention
Engine bearer and bearer of the v-belt pulley
are maintenance-free and must never be
lubricated!
15

Publicité

Table des Matières
loading

Table des Matières