Vacuuming Dry Objects - Fimap FE A65.2 DP Manuel D'utilisation Et D'entretien

Masquer les pouces Voir aussi pour FE A65.2 DP:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SUCTION OF LIQUIDS OR MOIST OBJECTS
To aspirate wet objects do the following:
1. Carry out all the instructions in the paragraph "Preparing the appliance".
2. Connect the male Connector (1) of the detergent Solution Distribution Tube (2) to the female
connector (3) on the suction head (Fig. 1).
3. Insert the suction pipe (4) into the suction nozzle (5) in the collection shaft, before inserting the suction
pipe, press the button (6) to release the latch (Fig. 2).
4. Insert the plug (7) in the power supply cable (8) into the mains socket (9) (Fig. 3).
ATTENTION: Do not exceed the maximum network impedance allowed for the electrical
connection point (see Technical data). If you have any doubts about the network impedance on
the connection point, please contact your electric power supplier.
PRUDENCE: Do not plug the power cord into the mains socket with wet hands.
5. Switch on the appliance by turning the main switch (10) to the "I" position (Fig. 4).
6. Start work.
3
5
1
4
2
1
2
IMPORTANT: If the type of work requires it activate also the second suction motor.
IMPORTANT: The machine is equipped with a mechanical device (float) placed under the suction
cover which, when the collection drum is full, closes the air passage to the suction motor,
protecting, in this case the sound of the suction motor It will be more gloomy. Drain the collection
drum (see paragraph "emptying the collection Drum").
If during work you notice that the suction power is reduced or the noise of the unit becomes stronger:
Switch off the appliance, set the main switch (10) to the resting position (Fig. 4).
10
4
Remove the plug (7) from the power supply cable (8) from the mains socket (9) (Fig. 3).
WARNING: To avoid damage to the mains socket, disconnect the plug from the mains socket by
pulling the plug directly instead of the power cord.
Remove the suction head (11) by means of the handle above it, before removing the head loosen the
retaining hooks (12) Located on the side of the collection Drum (13) (Fig. 5).
IMPORTANT: Before removing the suction cover, remember to unscrew the CAP (14) in the
solution tank (Fig. 6).
Empty the collecting drum (read paragraph "DRAINING THE COLLECTION TANK").).
IMPORTANT: The place used for this operation must be in compliance with the rules in force for
the environment.
If present, remove the optional sponge filter (15) (Fig. 7) and clean it, wipe the mechanical float with
a damp cloth (16) (Fig. 8).
When dry refit the sponge filter.
Repeat the operations backwards to return to work.
11
14
12
13
5
6
16
8
To vacuum dry objects, do as follows:
1. Check that both the general switches (1) are switched off, otherwise take them to the "0" position
(Fig. 1).
2. Check that the plug (2) in the power supply cable (3) is disconnected from the socket (4) of the mains
supply, otherwise disconnect it (Fig. 2).
3. Remove the suction head (5) by means of the handle above it, before removing the head loosen the
retaining hooks (7) Located on the side of the collection shaft (6) (Fig. 3).
1
6
9
7
8
3
4. Check that the fabric filter (9) is correctly positioned (Fig. 5).
5. Refit the suction head (5) above the collection frame (6), remember to fix it using the retaining hooks
(7).
6. Insert the suction pipe (10) into the suction nozzle (11) present in the collection drum, before inserting
the suction pipe, press button (12) to release the latch (Fig. 6).
7. Insert the plug (2) in the power supply cable (3) into the mains socket (4) (Fig. 2).
8
8. Switch on the appliance by turning the main switch (1) to the "I" position (Fig. 1).
9. Start work.
If during work you notice that the suction power is reduced or the noise of the unit becomes stronger:
Switch off the appliance, turn the main switch (1) to the resting position (Fig. 1).
Rimuovere la spina (2) presente nel cavo di alimentazione (3) dalla presa della rete di alimentazione
(4) (Fig.2).
10. Remove the suction head (5) by means of the handle above it, before removing the head loosen the
retaining hooks (7) Located on the side of the collection shaft (6) (Fig. 3).
Remove the Fabric filter (9) from the inside of the Keg (Fig. 7), shake and clean the fabric filter.
15
7
Repeat the operations backwards to return to work.
9
33

VACUUMING DRY OBJECTS

WARNING: To prevent damage to the power cord, disconnect the mains plug from the mains
socket by pulling the plug directly instead of the cable.
4
2
3
1
2
IMPORTANT: Before removing the suction cover, remember to unscrew the plug (8) in the
solution tank (Fig. 4).
IMPOIRTANT: For dry use, it is advisable to check that the inside of the collection shaft is dry.
9
5
4
WARNING: Do not exceed the maximum network impedance allowed for the electrical connection
point (see Technical data). If you have any doubts about the network impedance on the connection
point, please contact your electric power supplier.
PRUDENCE: Do not plug the power cord into the mains socket with wet hands.
IMPORTANT: If the type of work requires it activate also the second suction motor.
WARNING: To avoid damage to the mains socket, disconnect the plug from the mains socket by
pulling the plug directly instead of the power cord.
IMPORTNAT: Before removing the suction cover, remember to unscrew the plug (8) in the
solution tank (Fig. 4).
IMPORTANT: If the filter surface is extremely dirty, it is advisable to brush the filter to thoroughly
clean it with a normal soft brush.
Empty the collection drum.
IMPORTANT: The place used for this operation must be in compliance with the rules in force for
the environment.
IMPORTANT: If the previous operations have not solved the low suction switch off the machine
and remove the obstruction from the suction pipe or from the accessory you are using.
7
5
6
7
3
11
10
6

Publicité

Table des Matières
loading

Table des Matières