DANGER
Electric shock
risk
Technical Data
Mains voltage / Frequency
Absorbed power
Type of protection / Insulation class
Delivery fitting
Maximum flow rate
Maximum head
Maximum depth of immersion
Power cable
Weight
Maximum dimension of pumped solid
particles
Maximum temperature of the pumped fluid
(in servizio continuo)
Maximum number of starts per hour
(uniformly distributed)
Minimum priming level (A)*
Minimum suction level (B)*
Connection level (C)*
Stop level (D)*
Sound pressure level (Lpa) equal to or less than 70 dB(A)
Sound emission values obtained in conformity with the EN 12639 standard
(*) These data refer to Fig. 1. Measurements are expressed in millimetres.
The minimum priming level corresponds to a condition in which the delivery mouth is completely submersed.
(See Fig. 1 - Reference A).
If these pumps are used in continuous mode for ponds with fish, it is necessary to check them at regular intervals of 6
months (if the water contains aggressive substances). It is also advisable to check the maximum dimension of particles
recommended for the pump and take the necessary measures to prevent the fish from being sucked into the pump.
Ch. 3 Installation
DANGER
Electric shock
risk
DANGER
DANGER
WARNING
Use the handle provided to transport or lift the pump.
To use the pump in permanent installations with rigid pipes, to install a check valve to avoid the fluid being re-circulated
once the pump is stopped. The installation of a quick closing fitting in a convenient position facilitates cleaning and
maintenance operations.
The dimensions of the collection basin should reduce to the minimum the number of start-ups per hour (see LIMITA-
TIONS – Technical data).
To use the pump for temporary applications, install a flexible pipe and connect it to the pump using a pipe holder. To
immerse the pump, use a rope and fix it to the handle.
FLOTEC BIOX pumps have a pre-set floating switch. To change the setting, it is necessary to increase or reduce the
length of the floating switch cable by sliding it in the slot on the handle (See Fig. 1).
6
Make sure people do not come into contact with water when the pump is
connected to the mains.
BIOX 200/8A
230 V ~ 50 Hz
900 Watt
IP 68 / F
47,80 mm (1"1/2 M)
17.000 l/h
9 m
7 m
10m H07 RN8-F
(10m H07 RNF _ N2091021)
9,8 Kg
40 mm
40° C
30
123 mm
45 mm
370 mm
250 mm
When installing, please ensure electropump is disconnected from electrical supply.
Pumps in this series are not suitable for use in a swimming pool and the relevant
cleaning and servicing operations.
To prevent possible injuries to people, avoid inserting hands into the mouth of the
pump if this is connected to the mains.
The pumps of this series are not suitable to be used for swimming pools.
This appliance can be used by children aged 8 years or over and by persons with limited
physical, sensory or intellectual capabilities, or with limited experience and knowledge,
provided that they are supervised or have been instructed in the safe use of the appliance
and are aware of the dangers involved. Children must not be allowed to play with the
appliance. Cleaning and user maintenance must not be carried out by children unless
they are supervised
Pollution of the liquid could occur due to the leakage of lubricants
GB
BIOX 300/10A
230 V ~ 50 Hz
1300 Watt
IP 68 / F
59,61 mm (2"M)
21.000 l/h
11 m
7 m
10 m H07 RNF
11,2 Kg
40 mm
40° C
30
123 mm
45 mm
400 mm
300 mm
2
BIOX 400/12A
230 V ~ 50 Hz
1600 Watt
IP 68 / F
59,61 mm (2"M)
27.000 l/h
12 m
7 m
10 m H07 RNF
11,3 Kg
40 mm
40° C
30
123 mm
45 mm
400 mm
300 mm