Valve soiled or clogged
Pressure gauge does not show full pressure
The high pressure hose vibrates
Water exits intermittently
Valves can become clogged if you have not used the
device for an extended period
1.
If a valve is clogged,
2. the manometer will show little or no pressure
3. or the high pressure hose will vibrate
4. Use a ring spanner to open the valve
5. and remove the valve screw, the valve and the rubber
ring
6. bend a paper clip to the right shape ...
7. and use it to remove the dirt from the valve
• the inside valve must be closed
8. Water can escape at these three points. Push the
rubber seal back in tight
9. re-tighten the valve screw!
10. and repeat this for all 6 valves
11. This is how quickly you can eliminate the fault