3.
Hold both of the precisely overlapping straps
firmly using your left hand. Using your
right hand take hold of the lifting lever (c)
and cutting lever (b) and press together.
Push both straps laterally along the housing
wall into the tool as far as possible. A bit of the
lower strap has to project out of the front of the
tool. Release the levers (c) and (b).
4.
Using your right hand turn the ring of the
turning valve (a) to the left, to the limit.
The motor starts to run and tensions the strap.
After reaching the desired strap tension release
the ring. The turning valve closes automatically,
the motor is stopped. (The strap tension is
maintained by a free-wheeling mechanism.)
5.
The right hand takes hold of the compressed
air motor (f), the left hand grasps the cutting
lever (b) and pushes it rapidly forward up to the
stop at the housing. Thus the TITAN "no-seal-
joint" is formed. At the same time the steel strap
is cut off directly behind the joint.
HPE
H 224 EU 21/06