Remedying Faults - Pentair Jung Pumpen U3 K Instructions De Service

Masquer les pouces Voir aussi pour U3 K:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
QUICK TIPS FOR

REMEDYING FAULTS

Pump does not work
• Check mains current (do not use a pin gauge)
• Fuse faulty = may be too weak (please refer to
Electrical Connection)
• Mains supply cable damaged = repair to be
carried out by manufacturer only
Pump runs but does not pump
• Empty the pressure pipe or hose to allow the
non-return valve to open and the air to escape
from the pump housing, it may be necessary
to carry out a ventilation drilling
Impeller blocked
• Solids and fibrous matter have become lod-
ged in the pump housing = clean
Decreased pumping performance
• Foot strainer obstructed = clean
• Pressure pipe obstructed = clean
• Rotor worn out = repair to be carried out by
the manufacturer
• Wrong direction of rotation (for a three-pha-
se current) = ask a qualified electrician to
change 2 phases of the supply line
ENGLISH
JUNG PUMPEN GmbH - Industriestr. 4-6
33803 Steinhagen, Germany
401.14.1810
EN 12050-2:2001
Lifting plant for faecal-free wastewater DN 32
U3 K (JP00205/2)
U3 K spez. (JP09562/2)
U3 KS (JP00206/2)
U3 K spez. (JP44255)
U3 KS (JP09808/2)
U3 KS spez. (JP09563/2)
U3 KS spez. (JP45195)
Collecting and automatically lifting faecal-free
waste water above the backflow level in buildings
and sites
REACTION TO FIRE
WATERTIGHTNESS
EFFECTIVENESS (LIFTING EFFECT
- Pumping of solids
- Pipe connections
- Ventilation
- Minimum flow velocity
- Minimum free passage of the plant
- Minimum useful volume
MECHANICAL RESISTANCE
- Load bearing capacity and structural
stability of collection tank for use
- Structural stability of collection tank
for use inside buildings
NOISE LEVEL
DURABILITY
- of structural stability
- of lifting effectiveness
- of mechanical resistance
DANGEROUS SUBSTANCES
0197
13
U5 K (JP09386/0)
U5 KS (JP09387/0)
U5 KS (JP09417/0)
U6 K E (JP00226/2)
U6 K D (JP00228/3)
U6 K ES (JP00227/2)
U6 K ES (JP09260/2)
U6 K DS (JP00229/3)
U6 K DS (JP09261/3)
NPD
Pass
Pass
Pass
NPD
Pass
Pass
NPD
NPD
NPD
70 dB(A)
NPD
Pass
NPD
NPD
15 15