Annual servicing / disassembly
At least once a year, the entire plant has to be
serviced. In case of unfavourable conditions, such as
a lot of mud, and in case of decreasing performance,
the intervals have to be shortened. Whilst servicing,
no skimming will take place, which is no risk for the
inhabitants of the aquarium for about an hour.
Shut down the pump, and remove the Nano Cleaner
from the tank.
Remove the filter media (1).
Open the lower locking plate (2).
Remove the flow deflector (3).
Remove the pump (4) and service (see Silence
1073.008 / Servicing).
Remove and clean the protective grid (5).
Rinse the complete filter housing and remove any
algae.
Reassemble the various components; start up the
plant.
Entretien annuel / Démontage
Nous conseillons de réaliser un entretien complet
de l'appareil par an. Lors de conditions de
fonctionnement difficiles comme par ex. une forte
précipitation calcique dans la pompe, beaucoup de
mucus ou une diminution des performances, cet
entretien pourrait intervenir plus tôt. Durant cette
intervention d'une heure, l'aquarium est privé de sa
filtration ce qui ne devrait pas présenter de risques
pour les animaux.
Arrêtez la pompe puis retirer Nano Cleaner de
l'aquarium.
Retirez la masse filtrante (1).
Retirez le couvercle inférieur (2).
Retirez le déflecteur de flux (3).
Retirez la pompe (4) et réalisez son entretien, voir
aussi Silence 1073.008 / Entretien.
Retirez et nettoyez la grille d'aspiration (5).
Rincez entièrement le corps du filtre et retirez les
algues éventuelles.
Remontez les différents composants et démarrez
l'installation.