Technical Data
HxWxL
Weight
Inlet
Collection in container
Hose length rek.max.
Flow, max
Neg. pressure, max
Power consumption
Fine fi lter polyester, area
Degree of separation
(DIN 24184/3)
Soundlevel */
*/ Sound level at 1.6 m height and 1 m distance according to DIN
45635 Section 1 (4/84) in free space and at maximum airfl ow.
Description
Th e DC 5800i 11 kW P is stable, tough and reliable and
particularly suited to spot extraction in many diff erent app-
lications ie welding, grinding, sanding and cleanup.
With a very low sound level, the DC 5800i 11 kW P is sui-
table for use in areas which are sensitive to noise. Th e DC
5800i 11 kW P is driven by a 3-phase, turbo pump.
Operation
Connect the machine to a suitable power source according
to the specifi cations found on the identi-fi cation label on
the machine. If an extension cord is to be used with the
unit, it should be suitably rated according to the prevailing
electrical code and be at least water resistant. Check rotation
of the motor at startup. On machines equipped with a phase
reverser, incorrect rotation can be easily changed. Machines
not equipped with a phase reverser will require the service
of a qualifi ed electrician to interchange two phases in the
power supply.
Th e fi lter should be cleaned 1-2 times per day with conti-
nuous running or if the machine is equipped with a fi lter
monitor, when this is in the red area.
2011-08-16
1810x790x1400 mm
Capacity
240 kg
φ 108 mm
kPa
40
30 l
5-50 m
800 m
3
/h
28 kPa
20
9.2 kW
2
8.4 m
> 99.9 %
200
< 70 dB(A)
Material which has been extracted and separated is collected
in a 30 l container. Th e container can be removed with a
simple hand grip. Th e container can be moved using a pallet
truck. Th e collected material is easily handled in this way
for disposal or recycling.
Th e DC 5800i 11 kW P is equipped with wheels and is
therefore easily moved. For transportation over longer dis-
tances, the DC 5800i 11 kW P can be moved with forklift
or pallet truck.
For fi lter cleaning:
1.
Start the machine.
2.
Close the shutter valve on the machines inlet.
3.
With slow, even motion open the pulse top by lifting
the handle. Repeat three to six times.
4.
Open the shutter valve.
5.
If the fi lter condition meter reads green work can con-
tinue, if in the red, pulse clean again. If after several
repetitions, the fi lter condition still shows red the fi ne
fi lter must be changed.
DC 5800i 11 kW P - 9
DC 5800i 11 kW P
400
600
800
1000
Part No 9446-B
m
3
/h