Thanks to the mounting holes, you can install the flush mounting module behind a fixing
plate.
Tip: to simplify installing the camera module, use a Niko flush surround plate (10-896) (see
'2.2. Installation flush surround plate').
b. Horizontal and vertical detection range (fig.2)
VIEW FROM ABOVE
Horizontal opening angle
140 cm
50°
Recommended mounting height:
- standing persons: ±160cm (normal)
- children, wheelchair users: ±120cm
- sitting in a car: ±100 – 120cm
- sitting in a truck: ±180 – 220cm
Make sure the camera is installed outside the direct influence of:
- sunrays;
- strong light sources;
- highly reflective walls.
c. 5-wire connection (fig.3)
Connect the flush mounting module in a 5-wire
way by means of simple screw terminals.
Make sure you use the same colour combinations
as for the rest of the system.
Tip: for a good picture quality, use two wires of
one and the same twisted pair for V1 and V2.
EN
50°

SIDE VIEW

Vertical opening angle
fig.2
fig.3
10-496 / 10-896
60 cm
40°
40°