5.4 Flushing/Bleeding Filter Systems with and without Measuring and Display Unit
Note: A 10 litre bucket is required for fl ushing/draining.
•
•
•
•
•
•
•
Check system for any leaks.
•
Note installation date of the fi lter system and the next exchange date on the enclosed sticker
and attach it to the pressure vessel.
Note: There is space for several stickers on the pressure vessel. Apply the new sticker with the
installation date at the top position.
Note: Filter systems without measuring and display units are now ready for operation.
5.5 Checking initialisation of fi lter systems with a measuring and display unit
•
Bypass setting as a percentage, remaining capacity in litres, capacity bars and the current date
must be shown on the display.
Note: If these values are not shown in the display, the fi lter system must be fl ushed again
(Chapter 5.4) until the values are shown in the display. Filter systems with a measuring and
display unit are now ready for operation. Cf. Chapters 10.6 to 10.8.
28
Position fi lter system horizontally.
Completely open fl ush valve
Fully open the inlet valve
the bucket. Flush with at least 10 litres of water with a minimum volumetric
fl ow of 3 l/min (180 l/h).
Close fl ush valve
, put down fi lter and empty bucket.
9
Carefully open fl ush valve
Flush quantity once again with at least 10 litres.
Close fl ush valve
.
9
.
9
at inlet hose
while holding the fl ush hose in
7
6
while holding the fl ush hose in the bucket.
9