Press and hold the button (> 2 seconds) until the value
for the water hardness rises and keep it pressed until
the desired value has been reached.
•
Press the button (< 1 second) to access the next
parameter input monthly limit. The monthly limit input
fl ashes.
•
Press the button (> 2 seconds) and keep it pressed
until the desired value has been reached.
The set parameters can now be accepted.
If you want to accept the parameters, proceed as follows:
•
Press the button once (< 1 second) until the message
"Reset" appears and fl ashes.
•
Press the button once (> 2 seconds) until the total
capacity (at 0% bypass) and the current date appear.
The set parameters have been accepted.
Note: If no input is made within 30 seconds, the display will return to standby or operating mode
without accepting amended parameters.
•
Insert the display unit from the front at a height of approx. 10 mm and slide down. The loops on
the display part must be inserted in the grooves on the measuring head. Continue with Chapter
5.4 Flushing/Draining for Filter Systems with and without Measuring and Display Unit.
5.3 Bypass Setting
Determining the bypass setting
The bypass setting is identifi ed according to the application and the carbonate hardness identifi ed
on the basis of the bypass and capacity table (Chapter 7). The bypass is then set on the bypass
screw
as follows:
19
Turn the bypass screw
Caution: Use 6 mm or 7/32" Allen key.
!
until the desired bypass (0–3) agrees with the marking.
19
> 2 sec
< 1 sec
> 2 sec
< 1 sec
> 2 sec
27